![YASKAWA A1000 Series Product Replacement Manual Download Page 29](http://html2.mh-extra.com/html/yaskawa/a1000-series/a1000-series_product-replacement-manual_3210649029.webp)
VAN-V17001E<1>, Replacing A1000 crane with CR700
29/44
4.
Dimensions and Installation Attachments
4-1.
Exterior and Mounting Dimensions
Installation holes are not the same in A1000 and CR700.
The standard model A1000 (200/400V
㻌
22kW or less) is compliant for a wall-mount enclosure, while the
standard model CR700 has an open-chassis design (IP20).
An option is required to install CR700 in a wall-mount enclosure.
A UL Type 1 kit needs to be installed to the open-chassis (IP20) CR700. (Refer to Section 4-2)
A1000
CR700
Open Type Enclosure (IP20): Remove the top
cover for compliance
Open Type Enclosure (IP20): Standard model is
compliant
Enclosed wall-mounted type (UL Type 1
enclosure): Standard model is compliant
Enclosed wall-mounted type (UL Type 1 enclosure):
Option required for compliance