background image

-

 

  -

2

Safety Information

Read this instruction manual and the related documents thoroughly before installation, operation, maintenance
or inspection of this product.  Make sure you understand product information,all precautions and safety
information before using the product.   Also, keep this manual in a convenient location so that it can be
referred to whenever necessary.

The following conventions are used to indicate precautions in this manual.

Indicates precautions that, if not heeded, could possibly result in loss
of life or serious injury.

Indicates precautions that, if not heeded, could result in relatively
serious or minor injury, damage to the product, or faulty operation.

Even items described in   

CAUTION

    may result in a vital acccident in some situations.

In either case, follow these important notes.

                        : Items to be observed by users are described in the relevant sections.

 CAUTION

 

A CMOS IC is used for the Option Card.    Handle the control board and CMOS IC
carefully.    The CMOS IC can be destroyed by static electricity if touched directly.

 

To remove this option card from the inverter and transport or store it separately,
keep the option card in the anti-static electricity package used to protect the unit at
delivery.

 

Do not change the wiring or remove/insert the connectors while the power is turned
ON.

Failure to observe this caution may result in injury.

The PROFIBUS-DP Communication Interface Card SI-P1 is an option card that can be mounted on the
inverter control circuit board and used for communications with the PROFIBUS-DP master.
Three types of I/O data length (32 bytes, 12bytes, 6bytes) can be selected. The run/stop status can be
monitored and the inverter internal constants can be set/changed from the PROFIBUS-DP master.

NOTE

CAUTION

WARNING

AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France

Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

Summary of Contents for 73600-C033X

Page 1: ...AUDIN 7 bis rue de Tinqueux 51100 Reims France Tel 03 26 04 20 21 Fax 03 26 04 28 20 Web http www audin fr Email info audin fr ...

Page 2: ...cribed in the relevant sections CAUTION A CMOS IC is used for the Option Card Handle the control board and CMOS IC carefully The CMOS IC can be destroyed by static electricity if touched directly To remove this option card from the inverter and transport or store it separately keep the option card in the anti static electricity package used to protect the unit at delivery Do not change the wiring ...

Page 3: ...the instruction manual of the inverter on which the PROFIBUS DP Communications Interface Card SI P1 is to be mounted before using the PROFIBUS DP Communications Interface Card SI P1 2 Connect the PROFIBUS DP communications interface card SI P1 to the connectors or external terminals where the inverter power supply is turned OFF and the inverter CHARGE indicator lamp is extinguished 3 Specify the n...

Page 4: ...front cover Confirm that the CHARGE indicator lamp is extinguished 2 Fit the SI P1 card connector JP1 to the connector 2CN number of pins 60P on the inverter control board At this time insert the two SI P1 card spacer mounting holes into the option card spacer on the control board until a click is heard and mount the SI P1 card firmly See part in the side view 3 Connect the ground lead wire to the...

Page 5: ... Option D Connector Control Terminal Ground Terminal E G Ground Terminal E Inverter Control PC board Option A Option C Option D SI P1 Front View For F7 Series Side View For F7 Series A 4CN Option A Connector 2CN Option C Connector Fig 2 Installation of PROFIBUS DP Communications Interface Card SI P1 AUDIN 7 bis rue de Tinqueux 51100 Reims France Tel 03 26 04 20 21 Fax 03 26 04 28 20 Web http www a...

Page 6: ...ir cable conforming to the PROFIBUS specifications for the communications cable NOTE 8 3 R D T D N R D T D P 9 pin D SUB 1 2 3 4 5 6 R D T D N R D T D P Shield SI P1 Card Inverter Bus Connection Terminal PROFIBUS DP Master 2CN 60P PE 12 R L1 S L2 T L3 U T1 V T2 W T3 M 2CN 60P 3 phase Power Supply P Motor JP3 G5 series use terminal 12 F7 series use terminal E G AUDIN 7 bis rue de Tinqueux 51100 Rei...

Page 7: ...5 28 16 8 160 UL 30 14 8 300 CSA 28 16 8 300 2 Refer to Fig 4 for an illustration of how the end of the connecting cable on the SI P1 card s side should be prepared 3 Use a thin screwdriver less than 2 5mm wide and less than 0 4mm thick to loosen the terminal screw 4 Connect the SI P1 card s terminal block No 3 with the PROFIBUS DP master s No 8 pin and connect the SI P1 card terminal block No 4 w...

Page 8: ...sion line When the SI P1 card is connected as the end unit of the communications line the termination resistor selector switch ON of the SI P1 card will connect the termination resistor Termination resistors do not have to be mounted externally 5 1 3 Setting of Communications Speed When the communications speed is set on the PROFIBUS DP master the speed for the SI P1 card is also automatically set...

Page 9: ...eleration stop using deceleration time in C1 02 1 Coast to stop 2 Emergency stop using deceleration time in C1 09 3 Continue operation 2 1 F6 02 Input level of external error from Communications Option Card 0 Always detect 1 Detect during operation 0 F6 03 Stopping method for external error from Communications Option Card 0 Deceleration stop using deceleration time in C1 02 1 Coast to stop 2 Emerg...

Page 10: ... method selection 1 b1 02 Run Source 0 Digital Operator 1 Control circuit terminals sequence inputs 2 MEMOBUS communications usingSI K2 3 Option Card 4 MEMOBUS communications for CP 717 1 External Fault Input Level from Optical option F9 01 E 15 Selection 0 NO contact external fault at 1 1 NC contact external fault at 0 0 External Fault from Optical Option F9 02 EF0 Detection 0 Always detect 1 Det...

Page 11: ...e GSD file version is different Previous GSD file Revision Version1 0 New GSD file Revision Version3 1 Contact your Yaskawa representative to get the new GSD file for SI P1 card The new GSD file Version3 1 for SI P1 card is applicable to both the SI P1 card and the SI P card GSD files Version1 0 Version3 1 SI P card Applicable Applicable SI P1 card Not applicable Applicable AUDIN 7 bis rue de Tinq...

Reviews: