EXCITER LUBRICATION
The exciter housing is pre-serviced using Automatic Transmission
Fluid Dextron III, Mercon, EXXON (ESSO) NUTO H-32 or its
equivalent. Change fluid after 200 hours of operation.
1. Let exciter cool before changing exciter oil.
2. Remove the belt guard and V-belt(s).
3. Remove the bolts that hold the deck to the housing. (See
Figure 9a
)
4. lift entire deck with engine from housing.
5. Remove pipe plug from top of exciter housing. Tilt housing
upside down so oil drains from exciter. Examine oil for metal
chips as a precaution to future problems. (See
Figure 9b
)
6. Return plate housing to the upright position.
7. Fill the exciter housing with exciter oil. (See
Figure 9c
)
8. Apply pipe sealant to pipe plug and reinstall into top of exciter
housing.
9. Reinstall deck, V-belt(s) and belt guard.
When adjusting the belt(s), make sure that the clutch
pulley is in alignment with exciter pulley.
Do not overfill - overfilling can result in excessive
temperatures in the exciter.
When removing or installing the drive belt(s), be
careful not to get your fingers caught between the
belt and pulley.
Figure 9a
Figure 9c
Figure 9b
Exciter
Exciter Shaft
7. Move the engine back by hand until reach the right belt tension,
Refer to the
Figure 7b
to check the belt tension. Then lock the
jam nut.
8. Fasten the four engine mount bolts.
9. Attach the belt guard.
16
Plate Compactor
»
Operator’s Manual
Service
|
YC0850
60 ml
17
mm
18
mm
30
mm
13
mm
11
mm
5
mm
6
mm
29140US25M100.indd 16
2017/3/20 13:50:28