24
25
TROUBLESHOOTING
WARNING:
Always switch off the engine and pull the ignition cable before starting
any inspection or adjustment work.
If after making an adjustment or repair to the engine you let it run for a few minutes,
remember that the exhaust and other parts will get hot.
The following table provides solutions to common problems encountered with the
lawn mower:
Fault
Possible cause
Solution
Loud while
running,
machine
vibrates heavily
- Screws are loose
- Blade fasteners are loose
- Blade is unbalanced
- Check screws
- Check blade fasteners
- Replace blade
Engine does
not start
- Start/stop bar not pressed
- Primer bulb is empty
- Spark plug is defective
- Fuel tank is empty
- Engine may be flooded
- Press start/stop bar
- Press primer bulb 3-5 times
- Replace spark plug
- Refill with fuel
- Remove plug and dry,
Engine runs
unsteadily
- Air filter is soiled
- Spark plug is soiled
- Clean the air filter
- Clean the spark plug
Uneven
mowing results
- Blade is blunt
- Cutting height is too low
- Sharpen the blade
- Set correct height
Unsatisfactory
grass collection
- Cutting height is too low
- Blade is worn
- Grass bag is clogged
- Set correct height
- Replace the blade
- Clear any clogged grass debris
CE DECLARATION
To the provisions of Council Directives
We
SUMEC France Sarl
59 bis Rue du Mûrier
37540 Saint Cyr Sur Loire
France
Declare that the product:
Description: Petrol lawnmower
Model No. XSS40B/ GM R40
Function: Cutting grass
Complies with the essential health and safety requirements of the following
directives:
Machinery Directive 2006/42/EC
Electromagnetic Compatibility Directive 2014/30/EU
Noise Directive 2000/14/EC amended by 2005/88/EC
Conformity Assessment Procedure as Per Annex VI
Measured Sound Power Level: 90.2 dB (A)
Declared Guaranteed Sound Power Level: 96 dB (A)
Relative Notified Body (NB no 0865):
ISET S.r.l. Via Donatori del Sangue, 946024 - Moglia (MN)
Italy
Standards and technical specification referred to:
EN ISO 5395-1:2013+A1:2018
EN ISO 5395-2:2013+A1:2016+A2:2017
EN ISO 14982:2009
Authorized Signatory
Date: 24.01.2020
Signature:________________________
Place: Saint Cyr Sur Loire
Name: Rodolphe Dubois
General Manager
SUMEC France Sarl
59 bis Rue du Mûrier
37540 Saint Cyr Sur Loire
France