7. Load
8. Stopping your generator
When a large capacity battery is charged, excessive current
flows (the value varies depending on the discharging
condition), and the fuse for the direct current will burnout.
When charging a battery, the total load of the AC and DC
output should not exceed the continuous rated output.
WARNING:
Batteries produce explosive gases. Keep sparks, flames, and
cigarettes well away. To prevent the possibility of creating a
spark near the battery, always connect the charging cables
to the battery first and only then to the generator. When
disconnecting, you should disconnect the cables at the
generator first.
Charge the battery in a well-ventilated place.
Before charging, remove the cap from each cell of the
battery.
Discontinue charging if the electrolyte temperature exceeds
45°C (117°F).
CAUTION:
Do not attempt to start an automobile engine while the
generator is still connected to the battery. The generator
may be damaged.
CAUTION:
Do not use DC 12 volts and AC at the same time.
8. Stopping your generator
(1) Turn off the main switch of the generator.
(2) Low Oil Warning System Generator:
With the engine speed lever at “RUN” position, operate the
engine without load for about 3 minutes. Generators w/o Low