10.3.1 General malfunctions
Fault
Machine fails to drive
Cause
•
Left-hand armrest control panel lifted or switch defective
•
Pilot pressure too low or no pilot pressure at all
•
Low hydraulic oil level
•
Hydraulic pump has failed
Corrective
measure
Lower armrest panel.
Check pilot pressure
Top up the hydraulic oil to the mark
Have pump checked by specialist and replace if necessary
Fault
Poor travel performance
Cause
•
Engine output is insufficient
•
Pump has insufficient output
Corrective
measure
Check diesel engine
Check the pump and replace if necessary
Fault
Excavator equipment not working
Cause
•
Toggle switch for working hydraulics set to “OFF”
•
Left-hand armrest control panel lifted or switch defective
•
Switch on armrest panel defective
•
Oil supply to hydraulic pump interrupted
•
Hydraulic pump has failed
•
Main relief valves have failed
•
Maintenance cover folded down
•
Switch on maintenance cover defective
Corrective
measure
Switch the working hydraulics toggle switch
Lower armrest panel
Check the switch and repair or replace if necessary
Check lines
Have hydraulic pump checked by a specialist and replace, if necessary
Check main relief valves and replace, if necessary
Close maintenance cover
Repair or replace maintenance cover switch
Summary of Contents for B95W
Page 2: ......
Page 8: ...B95W Table of contents 6 306 1 01_Inhaltsverzeichnis_enIVZ fm V1 0 1 8 17 10 ...
Page 52: ...B95W Description 50 306 5 05_Beschreibung_en fm V1 0 1 8 17 11 ...
Page 58: ...B95W Description 56 306 5 05_Beschreibung_en fm V1 0 1 8 17 11 ...
Page 206: ...B95W Maintenance 204 306 6 06_Wartung und Pflege_en fm V1 0 1 8 17 20 ...
Page 208: ...B95W Operation 206 306 7 07_Bedienung_en fm V1 0 1 8 17 26 ...
Page 272: ...B95W Transport 270 306 8 08_Transport_en fm V1 0 1 8 17 27 ...
Page 302: ...B95W Troubleshooting 300 306 10 10_Fehlerbeseitigung_en fm V1 0 1 8 17 30 ...
Page 309: ......