Charge lamp does
V-belt broken or loose
Replace V-belt; adjust
4.3.5(1)
not go out
tension
during operation
Battery defective.
Check fluid level,
specific gravity;
replace.
4.3.2(3)
Alternator power
Ask for repairs.
generation failure
●
Starting Failures
○
Starter works
No fuel
Resupply fuel; bleed air.
3.2.1(1)
but engine does not
Improper fuel
Use recommended fuel.
3.1.1
start
Fuel injection faulty.
Ask for repairs.
Compression leaks from
intake/exhaust valve.
Ask for repairs.
○
Starter does not
Neutral safety switch engaged
Shift clutch to Neutral.
3.3.2(1)
work or works
Battery charging
Check fluid level;
4.3.2(3)
only slowly. (eng.can
insufficient.
re-charge; replace.
be turned manually)
Cable terminal contact
Remove rust from
failure
terminal; retighten.
Switch of safety
device faulty.
Ask for repairs.
Starter switch faulty.
Ask for repairs.
Battery power lacking due
to other use.
Consult your dealer.
○
Engine can't be turned
Internal parts seized;
Ask for repairs.
manually
broken.
●
Poor Exhaust Color
○
Black smoke
Load increased
Inspect propeller
system
Turbocharger blower
contaminated.
Clean blower.
Fuel improper.
Use recommended fuel
3.1.1
Faulty spraying by
F.O. injection valve
Int./exh. valve head
clearance excessive
Ask for repairs.
○
White smoke
Improper fuel
Use recommended fuel
3.1.1
Faulty spraying by
F.O. injection valve
Ask for repairs.
F.O. injection timing lags
Ask for repairs.
Lube oil burns;
excessive consumption
Ask for repairs.
Trouble
Probable Cause
Measure
Reference
_
47