OPERATIONS
Before operation make sure of correct power source and on leakage of
pipe/connectors. Both direction of the motor is suitable for the pump. (No need to
check the direction)
To change the flow rate, loosen the fix-nut then turn the flow regulator knob while the
pump is running. (Do not turn the flow regulator knob when pump is stop). Set the
indicator between 0-10 (clockwise to reduce flow rate the opposite to increase).
Indicator
Fix screw
flow regulator
knob
When indicator monitors at 10(100%), the stroke is at full length, when0(0%), it
means stroke is running at 0% of max. stroke length. The pump flow rate is
proportionally to the stroke length.