1.

Description  

 

 

The suspended solids sampler allows testing the quantities of suspended 
solids in water, as a step in a procedure of choosing appropriate filter for 
the application.  
 
Suspended solids are an important indicator of water quality. Knowing 
the amount of suspended solids in untreated water allows choosing the 
right filtration grade and screen area of the filter which will effectively 
treat the water, and will not require prolonged maintenance. Taking a 
well mixed sample is important for getting accurate results.  
 
The sampler is designed for use at the filtration site, not in laboratory. It 
is connected to the supply line of unfiltered water, and small part of the 
supply stream passes through it during the sampling time. Suspended 
solids are separated from the supply water and accumulated in a sample 
tube. The parameters of the filter are calculated using the amount of the 
suspended solids accumulated in the sample tube during the sampling 
time.  
  

2.

Application 

 

The suspended solids sampler is designed for use in:  

Filtration systems.  

Agricultural systems.  

Supply pipes.  

Water reservoirs.  
 

3.   Features 

 

Not affected by color of fluid or particulates.  

Measures suspended solids to thick for optical methods.  

Easy set-up and calibration.  

Non-clogging, smooth-bore, non-intrusive sensor, low maintenance 
due to absence of moving parts.  
 

F700 

Summary of Contents for F-700TS HYDROCYCLON

Page 1: ...S HYDROCYCLON Installation Operation Manual v 10 3 2020 Yamit Filtration Water Treatment Ltd PO Box 232 Moshav Tnuvot 428300 Israel Tel 972 4 6220006 Fax 972 4 6220042 e mail yamit yamit f com www yamit f com ...

Page 2: ...chnical Data 4 5 Installation 4 6 Sampling 5 7 Calculating the quantity of the suspended solids 6 8 IPB 7 9 International Warranty 8 ALL RIGHTS RESERVED THIS MANUAL AND THE INFORMATION CONTAINED ARE NOT ALLOWED TO BE USED WITHOUT WRITTEN PERMISSION FROM YAMIT FILTRATION F700 ...

Page 3: ...ation site not in laboratory It is connected to the supply line of unfiltered water and small part of the supply stream passes through it during the sampling time Suspended solids are separated from the supply water and accumulated in a sample tube The parameters of the filter are calculated using the amount of the suspended solids accumulated in the sample tube during the sampling time 2 Applicat...

Page 4: ...rtical direction the sample tube 4 is oriented downwards while the inlet 2 is horizontal and located at the level of the supply line 1 A 15 cm hose 120 cm 47 long should be connected to the outlet 5 of the sampler The opposite end of the hose should be open to the atmosphere in a place that splashing water would not cause any damage or danger In this setup the water that will flow through the samp...

Page 5: ...sampling period of time Close the inlet valve at the end of the sampling 5 When a sufficient amount of suspended solids has accumulated in test tube register its quantity in ml and the time required for the sample collection in min 6 Disconnect the sample tube and identify the size suspended solid particles 7 Clean the sample tube and connect it to the sampler The required amount of test periods i...

Page 6: ...ee in order to verify that no particle greater than the filtration grade has passed through the filter Calculation examples 1 For 2 ml of suspended solids collected during 6 min the suspended solids quantity of the supply lines is 2 For 6 ml of suspended solids collected during 3 min the suspended solids quantity of the supply lines is Suspended solids concentration ppm Amount of accumulated suspe...

Page 7: ...y NA 2 Test tube 4820000010 3 O Ring 4081020110 4 Elbow BSP 4170056501 5 Connector T BSP 4190056500 6 Bushing BSP 4640112141 7 Pressure gauge 4400102502 8 Ball valve 4504005100 01 9 O Ring 4081012100 112 10 Bushing BSP for Test tube 6126300701 ...

Page 8: ...of any kind or nature regardless of the nature thereof including without limitation injury to persons or property loss of use of the products loss of goodwill loss of profits or any other contingent liabilities of any kind or character alleged to be the cause of loss or damage to the purchaser This warranty does not cover damage or failure caused by misuse abuse or negligence nor shall it apply to...

Reviews: