![Yamato VFK2560-8 Instruction Manual Download Page 41](http://html.mh-extra.com/html/yamato/vfk2560-8/vfk2560-8_instruction-manual_905404041.webp)
34
VFK2560-8
When the looper is at the extreme right, the distance
between the looper ① tip and the center of the needle bar
is 5.5 ㎜ (5.5 - 5.7 ㎜ ) even if the needle distance differs.
Loosen the screw ④ of the looper holder to adjust this
distance.
6.8 Looper
6.8.1 Installing angle and height of looper
Insert the looper ① into the looper holder ② fully and
tighten the screw ③ securely.
It makes the height and installing angle (0° ).
Fig. 6-20
Fig. 6-21
6.8.2 Distance between looper and needle
①
②
③
④
5.5 ㎜ (5.5 - 5.7 ㎜ )
M
6. Adjustments
Table 8
Fig. 6-22
Needle distance
Looper's distance “M”
5.2 ㎜
2.9 - 3.1 ㎜
6.0 ㎜
2.5 - 2.7 ㎜
The distance “M”
between the looper tip and the center
of the right needle differs according to the needle dis-
tance so adjust to the distances shown in Table 8.