Page 1: ...al DIGITAL PLATFORM SCALE DP 6700 OPERATION MANUAL Read this manual and keep it handy YAMATO SCALE CO LTD EXPORT 1006...

Page 2: ...ns in it to use Yamato s DP 6700 in the optimum condition for the longest life TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS 1 INSTRUCTIONS AND DIRECTIONS FOR USE 3 FUNCTIONS 4 PRODUCT PACKAGE 5 NAMES OF...

Page 3: ...hibited Compulsion Denotes what must be followed NOTE Prior to use read carefully the following descriptions of Danger Warning and Caution to understand and comply with them Danger ToAvoid Electrical...

Page 4: ...t in fire injury or taint damage Do Not Heat Batteries or Put in Fire or Water Otherwise batteries may burst Set Batteries Correctly as Instructed for Polarity Otherwise batteries may leak or burst Do...

Page 5: ...ironment 2 Rapid temperature change even under less humid condition 3 Operation under such environment as chill from refrigerator steam or vapor 5 Do not spray alcohol chlorine or other chemicals dire...

Page 6: ...o use before shipment The setting can be changed following instructions on Parameter Setting 16 Addition total It is possible to add weighing result with Key operation or automatically You can conform...

Page 7: ...5 PRODUCT PACKAGE NAMES OF PARTS...

Page 8: ...rush and so on 4 When washing the whole scale with a neutral detergent apply a little neutral detergent to a sponge and wipe them Make sure to rinse them in clean water and wipe it thoroughly with a d...

Page 9: ...tion Inserting the pole into the pole bracket extending a slack in cable and taking care not to damage the cable Procedures 1 Insert the pole into the pole bracket 2 Set a screw at the center hole and...

Page 10: ...tery box Replace all 4 batteries with all new ones at once Do not use alkaline batteries and manganese batteries in mixing Note Make sure that both tabs are hanged firmly or its waterproof cannot be k...

Page 11: ...leveler The bottom of the scale is equipped with 4 leveling legs with which the scale is adjusted to be on the level Turn the levelling legs until the bubble locates at the center of the benchmark cir...

Page 12: ...Purple for rank 5 also for rank 12 Yellow for rank 6 also for rank 13 White for rank 7 also for rank 14 No light for out of range ON OFF key Turns the power on and turns the power off Power is turn o...

Page 13: ...indicators blinks 2 When zero does not appear since the zero point is not correctly recognized Press Zero appears on the display 3 Place the item s on the platform The display shows the weight of the...

Page 14: ...e container e g 2 kg is shown on the display 2 Press after the stable indicator is lit The NET indicator is lit and the display shows zero 3 Start weighing Place the item s in the container on the pla...

Page 15: ...use 10 minutes after no use 15 minutes after no use default 30 minutes after no use 60 minutes after no use 07 Flicker of weight display 000 001 002 003 004 005 No flicker default Flickers at under w...

Page 16: ...Parity 000 001 002 No parity default Odd parity Even parity 18 Stop bit 000 001 1 bit 2 bits 19 Print 000 001 No designation Only total weight is printed 23 Send display during transfer 000 001 008 No...

Page 17: ...Rank Max Item No No of Rank Max Item No 02 66 items 07 24 items 12 15 items 03 49 items 08 22 items 13 14 items 04 39 items 09 19 items 14 13 items 05 33 items 10 18 items 15 12 items 06 28 items 11...

Page 18: ...er setting mode 3 Press to move the parameter No from 01 to 05 Note When passing by 05 keep pressing until looping back to 05 4 Press or to change the value to 005 Note key move the value forward 1 ke...

Page 19: ...Note key move the value forward 1 key move the value backward 1 001 Automatic sending addition at being stable 002 Automatic sending addition after removal 003 Manual sending addition byADD key defau...

Page 20: ...is displayed and theADD indicator is lit Change over between manual and automatic addition 1 Press and at the same time In case that manual addition is set for the parameter 11 automatic addition is...

Page 21: ...is shown As the result of 2 and 3 the total weight is 123456 78kg 4 Press again Then the cycles of weighing 670 is shown In this case 670 cycles of weighing makes up the total weight of 123456 78kg I...

Page 22: ...imum 99 items Allowable range UNDER WEIGHT ACCEPTABLE WEIGHT OVER WEIGHT LED blinks LED lights LED lights LED lights LED blinks 0 kg Target wt Full capacity CHECKWEIGHING OVER UNDER FUNCTION Applicati...

Page 23: ...No In case of sorting items to 2 ranks max 66 items are available In case of sorting items to 15 ranks max 12 items are available e g Sorting the item to 2 ranks 0 g The lower limit The lower limit Th...

Page 24: ...Fixed weighing 002 Checkweighing 003 Grading 004 Counting The parameter changes to 02 when is pressed 3 Only when 003 Grading is selected Press 6 times to move to the parameter 08 and choose additive...

Page 25: ...weight 002 Beep at over weight 003 Beep at acceptable weight 004 Beep at under over weight 5 Press 4 times The display goes to the parameter 07 Flicker of weight display setting If you would like to f...

Page 26: ...the item number setting press The judgment lamp becomes blue and the target weight setting stage appears 5 Enter the target weight by pressing or Pressing changes the digit Pressing changes the value...

Page 27: ...ows the weight to the target weight as a negative number The red judgment lamp lights up or blinks when the weight is short e g When placing up to 8kg the display shows 2 00 7 Place the items on the p...

Page 28: ...er weight 002 Beep at over weight 003 Beep at acceptable weight 004 Beep at under over weight 5 Press until the display goes to the parameter 07 Flash setting If you would like to flash the weight dis...

Page 29: ...ard 1 moves the value forward 1 4 Press to store the setting value The blue judgment lamp lights or blinks and the display switches to the lower limit setting stage 5 To set the lower limit press to s...

Page 30: ...Place the item s on the platform When the net weight is short against the acceptable weight 10 0kg to 11 00kg the red judgment lamp lights or blinks 6 When the net weight is in the range of acceptabl...

Page 31: ...d items are as below Value 002 003 004 005 006 007 008 009 010 011 012 013 014 015 No of ranks 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No of items 66 49 39 33 28 24 22 19 18 16 15 14 13 12 5 Press twice The...

Page 32: ...setting stage 3 Press or to chose the item number e g Item No 05 moves the value backward 1 moves the value forward 1 Press to store the setting value 4 Press again to go to the setting stage for rank...

Page 33: ...0kg or more set the upper limit at 300 10 Press Press to save the setting value and return to the set up screen Color judgment Rank 1 Blue Rank 8 15 the same color Rank 2 Green Rank 9 the same color R...

Page 34: ...empty container on the pan and press 4 Place the item on the pan The display shows the rank of the item e g When the net weight of the item is 2 50kg the rank shows 02 Note In case of subtractive grad...

Page 35: ...number 2 Press or to set the sampling number at 100 moves the number 10 20 50 100 200 moves the number 200 100 50 20 10 Press after setting the sampling number 3 Place on the platform 100 pieces of s...

Page 36: ...s in red when no stored unit weight exists 2 Place the items on the pan The counting starts and the display shows quantity calculated by the total weight and unit weight e g Quantity 670 pieces 3 Pres...

Page 37: ...with new ones The weight below zero This message appears when the weighed value is less than 5 divisions Press If the stainless steel platform cover has been removed set it on the scale again The over...

Page 38: ...Turned on the scale while the item was left on the platform And then removed it and pressed Make sure that nothing is left on the platform and turn on the scale again The data overflow error The stor...

Page 39: ...eapply the power after a brief interval When the scale does not return to normal contact the dealer Calibaration error The weights used for the calibration may be incorrect Re calibrate the scale with...

Page 40: ...when a trouble was detected in the electronic circuit Turn off the scale And reapply the power after a brief interval When the scale does not return to normal contact the dealer Trouble in electronic...

Page 41: ...t Turn off the scale And reapply the power after a brief interval When the scale does not return to normal contact the dealer Trouble in electronic circuit This message appears when a trouble was dete...

Page 42: ...r 3 levels of remaining battery Zero indicator Lights up at center of zero range Net indicator Lights up at tare operation Auto indicator Lights up at automatic mode Add indicator Lights up when accum...

Page 43: ...ing function Piece count can be calculated 8 Appearance Outside dimensions 350W x 605D x 795 802H mm Weight Approx 13 kg including batteries Material Stainless steel SUS304 Upper housing Pan 9 Waterpr...

Page 44: ...YAMATO SCALE CO LTD 5 22 Saenba cho Akashi 673 8688 Japan Telephone 81 78 918 6157 Telefax 81 78 918 5562 PRINTED IN JAPAN...