background image

7

部品の確認 /

Confirmation of Packing Contents

梱包箱の中には、以下の部品が入っています。
組み立ての前に、すべての部品がそろっていること
を確認してください。

※ 部品が不足している場合は、お買い求めになったお店

へご連絡ください。

t

 共鳴パイプ ( 幹音側 )

t

 

Resonators (Natural tone side)

r

 支柱

r

 

Reinforcement stay

The shipping carton of your xylophone should 
contain the parts shown below. 
Before assembling the instrument, confirm that all 
parts are included as listed. 

*  In  the  event  that  a  part  is  missing,  please  contact  the 

shop where the instrument was purchased.

w

 幹音板

w

 

Natural tone bars

e

 派生音板

e

 

Accidental tone bars

q

 枠集成

q

 

Frame Assembly

y

 共鳴パイプ ( 派生音側 )

y

 

Resonators (Accidental tone side)

u

 取扱説明書 ( 本書 )

u

 

Owner’s Manual (This booklet)

組立手順 /

Assembly

安全のために、組み立ては 2 人以上で、十分スペー
スのある場所で行なってください。
床にじゅうたんや柔らかい布などを敷いておくとよ
いでしょう。

For safety, the instrument should be assembled 
and disassembled by at least two people in a loca-
tion with sufficient space. For additional precau-
tions, assemble the instrument on a soft rug or 
carpet.

 組立作業上のご注意

・  分解 / 組立の手順は、必ず本説明書の通りに 2 人以

上で行なってください。誤った手順で組み立てると、
パイプが落下し、けがの原因となったり、機能が十分
に働かなかったり、雑音発生の原因になったりします。

・  脚部のネジは、位置が決まったらしっかりと締め付け

て固定してください。ゆるんだ状態で使用すると演奏
中に楽器がずれたり、雑音が出たり、トラブルの原因
になります。またこれらのネジは時々締め直してお使
いください。

 Assembly Cautions

•  Follow  these  instructions  carefully.  Assembly  in  the 

wrong order can cause the pipes to drop, which may 
result in bodily injury or impair the performance of the 
instrument.

•  Note that after final assembly is complete, the fixing 

screws  must  be  tightened  securely.  Loose  screws 
or  bolts  may  cause  the  instrument  to  shift  during 
performance,  causing  noise  and  other  problems. 
Retighten the screws regularly.

yx500.indd   7

14/10/10   10:43

Summary of Contents for YX500R

Page 1: ...er Gasfeder und die Vorsichtsma regeln Lire attentivement les paragraphes Pr cautions de manipulation du ressort gaz et Pr cautions observer Lea sin falta las Precauciones para la manipulaci n del mue...

Page 2: ...ause trouble during performance such as unexpect ed movement etc or parts falling off during transport resulting in injury Be careful not to pinch your fingers or hands when assembling Doing so may ca...

Page 3: ...ply a high tensile load to the gas spring as it will cause damage to the gas spring In the event of a failure stop using the instrument and contact the shop where you pur chased it If your dealer is u...

Page 4: ...4 2 YX500R 35kg YX500F 38kg 7 10 2 2 yx500 indd 4 14 10 10 10 43...

Page 5: ...5 2 20 50 1 yx500 indd 5 14 10 10 10 43...

Page 6: ...rake Accidental tone bars Natural tone bars Leg Bass side Rail Resonators Natural tone side Resonators Accidental tone side Reinforcement stay Frame end Treble side Stay Caster with brake Caster Caste...

Page 7: ...s booklet Assembly 2 For safety the instrument should be assembled and disassembled by at least two people in a loca tion with sufficient space For additional precau tions assemble the instrument on a...

Page 8: ...ched fingers or hands For this reason installing the stay should be done by at least two people One person should hold the legs to prevent them from falling over while the other person inserts the sta...

Page 9: ...tallation 4 1 First pass the resonators through the frame from underneath the rail and then mount the treble end into the resonator rest 4 2 Next mount the bass side Pass the end of the resonators thr...

Page 10: ...hook the two springs onto each other Take care not to cause any damage to the tone bars when setting them n Adjust tone bar height Make sure that this procedure is performed by at least two people so...

Page 11: ...type Caster 100 mm diameter with brake Dimensions W x D x H 137 5 x 75 x 80 95 cm 54 3 8 x 29 1 2 x 31 1 2 37 3 8 Weight 35 kg 77 lbs 3 oz YX500F Range F45 C88 3 1 2 octave Standard Pitch 442Hz Bars...

Page 12: ...WT48590 1410 R1 Printed in Japan...