Yamaha XM6150 Owner'S Manual Download Page 8

8

Air Flow

This unit uses a forced cooling system in which air comes in through the front opening and goes out the sides and
rear.

4-6.5 x 1

1

88

463

480

Unit : mm

248

4-C15

4-ø4.5 

76.2

71.5

±

0.1

71.5

±

0.1

78

78

Fan kit

Ventilation panel

XM6150/4220

XM6150/4220

Rack Mounting

If multiple high-power amp units are mounted in a rack with poor ventilation, the heat from the amps will cause the
interior of the amp to become very hot, causing the performance of the amps to be impaired. In particular, when
mounting in a rack whose back can not be left open, mount according to the following instructions.

Rack: Leave a gap of 10 cm or more between the rear panel of the rack and the rear panel of the amplifier.
Fan: Use a fan with 1.5 m

3

/min or more maximum wind and 5 mmH

2

O or more maximum static pressure.

Mounting: Install the fan kit on the top slot or the top panel of the rack and install a blanking panel between two

amps.

Ventilation panel: . The ventilation panel should be a 1U size, and more than 35% of the entire area should be

open.

Example of mounting

The figure on the left below shows an example of a fan kit (panels and two fans) on the top slot of the rack. The fans
are Minebia 3115PS-12T-B30 (with 0.9 m

3

/min maximum wind and 5 mmH

2

O maximum static pressure).

The figure on the right below is a dimensional diagram of a panel on which two 3115PS-12T-B30 are installed.

80

Side View

Rear View

Air intake

Air exhaust

Air exhaust

Front

Summary of Contents for XM6150

Page 1: ...POWER AMPLIFIER XM6150 XM4220 Owner s Manual E...

Page 2: ...ow noise cooling fan system ensures high reliability even under the most demanding conditions This Owner s Manual applies to the XM6150 6CH and XM4220 4CH power amplifier In order to take full advanta...

Page 3: ...for a replacement Using the unit with a damaged power cord is a fire and electrical shock hazard Do not remove the unit s cover You could receive an electrical shock If you think internal inspection...

Page 4: ...tes if a DC voltage is detected at the amplifier s outputs Once the DC voltage problem is corrected the protection system deactivates automatically and the amplifier is ready for normal operation If t...

Page 5: ...r C D and channel E of pair E F XM6150 only 80 1 3 4 8 7 5 2 6 4 Euroblock connectors These balanced Euroblock connectors are used to connect input signals In Bridge mode only the Euroblock connector...

Page 6: ...e operation Normal mode Bridge mode Speaker min 8 Speaker min 4 Speaker min 4 In Bridge mode you can connect multiple high impedance speakers that are compatible with 70V line output in parallel The n...

Page 7: ...the cover attachment screws and remove the protective cover from the speaker terminals Screw 3 After removing approx 15 mm of insulation from the ends of the speaker cables pass the bare ends of the s...

Page 8: ...10 cm or more between the rear panel of the rack and the rear panel of the amplifier Fan Use a fan with 1 5 m3 min or more maximum wind and 5 mmH2 O or more maximum static pressure Mounting Install th...

Page 9: ...ed 15 k Unbalanced Controls Front Panel POWER switch ON OFF Rear Panel Volume 31 position ch BRIDGE switch ON OFF 2ch HPFswitch ON OFF ch fc 80 Hz 12 dB oct CH A TO ALL CH switch Connectors Input XLR...

Page 10: ...10 Block Diagram Note The block diagram indicated in the dotted frame applies only to model XM6150...

Page 11: ...11 Dimensions Unit mm D 319 W 480 H 132...

Page 12: ...mpedance of the connected speaker is too low The heat sink temperature has exceeded 90 C A DC voltage of 2 V or greater was detected in the amplifier s output circuit Locate and remove the short Check...

Page 13: ...YAMAHA CORPORATION V455890 R0 1 AP 16 Pro Audio Division 18 3 P O Box 3 Hamamatsu 430 8651 Japan NP Printed in Taiwan...