3
Data setting
3-17
Settings
Setting value
Description
0
Closed mode
1
Open mode
TIP
For details regarding the stop mode, see section 7.5, "Stop mode", in Chapter 5.
K124
Stop mode switching time
Setting Range
Default
Units
Restart
0 to 5000
200
ms
-
Function
Specifies the time to wait before shifting to the stop mode after positioning is completed.
K125
Holding current during
stop
Setting Range
Default
Units
Restart
0 to 100
Depends on robot type
%
-
Function
Specifies the holding current when the stop mode is in open mode. A setting of 100% is the rated current for each robot
type.
4.2.4 Option parameters
K80
Option enable
Setting Range
Default
Units
Restart
0 to 1
1
-
-
Function
Specifies the I/O enable/disable setting.
Settings
Setting Value
Description
0
Disable
1
Enable
4.2.5 CC-Link
K81
CC-Link node
Setting Range
Default
Units
Restart
1 to 64
1
-
Required
Function
Specifies the CC-Link communication node.
K82
CC-Link speed
Setting Range
Default
Units
Restart
0 to 4
4
-
Required
Function
Specifies the CC-Link baud rate.
Settings
Setting Value
Description
0
156Kbps
1
625Kbps
2
2.5Mbps
3
5Mbps
4
10Mbps
c
CAutIoN
the baud rate setting specified here must be the same as the baud rate specified at the master station. A normal
data link cannot be established if the settings are not the same.