Installation and wiring
2-24
10.3 Circuit details
The following shows an EXT connector and host unit connection example.
Status
Safety circuit
TS-X TS-P
External
0V
External
"emergency
stop"
E
S
+
E
S
1
E
S
2
E
S
-
L1
N1
L
N
External 24V
Internal
power
ES
EXT connector
COM1
Controller
NO
NC
MPRD
Y1
MPRD
Y2
Handy Terminal
+
2
4
V
0
V
1 2 3 4 5 6 7 8
Internal
GND
23214-M1-00
w
DANGER
IN oRDER to flEXIBly ACCoMMoDAtE thE vARIouS SAfEty CAtEGoRIES REquIRED By CuStoMERS, thIS
CoNtRollER IS Not EquIppED WIth AN INtERNAl MAIN poWER Shutoff CIRCuIt.
thEREfoRE, BE SuRE to INStAll AN EXtERNAl MAIN poWER Shutoff CIRCuIt AND AN "EMERGENCy Stop" CIRCuIt.
c
CAutIoN
Be sure to install a surge absorber unit at the electromagnetic contactor's coil.
Safety circuits connected in daisy chain
TS-X TS-P
External 0V
ES+ ES1
ES2
ES-
L1
N1
L
N
Internal
power
ES
status
EXT connector
COM1
Controller
Handy Terminal
Internal GND
NO
NC
MPRDY1
MPRDY2
ES+
ES1
ES2
ES-
ES
status
EXT connector
Controller
Internal GND
MPRDY1
MPRDY2
ES+
ES1
ES2
ES-
ES
status
EXT connector
Controller
Internal GND
MPRDY1
MPRDY2
L
N
NO
NC
L
N
NO
NC
External 0V
External 24V
External 24V
Internal
power
Internal
power
External 0V
Relay
*1
*2
*2
External 0V
23215-M1-00
w
DANGER
IN oRDER to flEXIBly ACCoMMoDAtE thE vARIouS SAfEty CAtEGoRIES REquIRED By CuStoMERS, thIS
CoNtRollER IS Not EquIppED WIth AN INtERNAl MAIN poWER Shutoff CIRCuIt.
BE SuRE to CoNfIGuRE AN EXtERNAl MAIN poWER Shutoff CIRCuIt to foRM AN EMERGENCy Stop CIRCuIt.
c
CAutIoN
• Be sure to check the contact capacity of the relay contact. If the capacity is insufficient, use multiple contacts
as needed. (*1 in the diagram)
• Connect a load with a current of 300 mA or less to the emergency stop wiring using ES1 and ES2. If a load with a
current of more than 300 mA is connected or if a current of more than 300 mA flows without connecting any
load, the controller may malfunction. (*2 in the diagram.)