  SAFETY INSTRUCTION

   

*Please read this manual carefully before use   

- The points quoted here are indispensable to using the product properly and to prevent hazards or damages to the user or   

other people.     

- After reading through, keep the manual at a safe place where you can consult it whenever necessary.     

- Please must follow the content of safety part   

 

* * Operating surroundings   

- Don’t use the massage chair under dusty, smeary and anoxic conditions.     
- Don’t use or store the massage chair under damp environment.     
- Don’t place the massage chair near heater, stove or sunlight radiation to avoid inner components overheating 

to cause fire    i.e. bathroom   

- Make sure to place the massage chair on a flat level ground   

 
*** 

If using massage chair in a very cold place, please don’t increase indoor temperature too quick but by 

increased gradually.   
If you’re moving massage chair from very cold place to warmer place, you should wait after 1 hour to start 

operate massage chair.   

As if cold mechanism is been operated by a warm indoor place, it might cause breakdown and effect the 

operation of massage chair.     

 

***   

*Children under 18 ages or special persons ( as psychopath, the mental defects, the paralysis) close are not 

allowed to operate the massage chair, in case of electric shock, injuries or mechanism malfunctions.     

* Be sure to keep children away from the machine to avoid any accident.     

* Any damaged wires or cable have to be repaired by manufacturer or repairing dept.   
 

* The following persons must consult their physician before using the product 

 

Who uses a medical electronic device which is embedded in the body, such as pacemaker 

             

 
 

 

 

 
 

 
 

 

P.2 

Summary of Contents for TF5

Page 1: ...ASSAGECHAI R Instruction Manuals Luxury Massage Chair MODEL NO TC 626 BE SURE TO READ THIS INSTRUCTION MANUALS CAREFULLY AND USE IT PROPERLY AFTER USE KEEP THIS MANUAL REACH AT ALL TIME FOR FUTURE USE...

Page 2: ...nual within reach at all time for future use CONTENTS IMPORTANT SAFETY INSTRUCTIONS 2 SPECIFICATION 4 CONSTRUCTION 5 INSTALLATION METHOD 7 PREPARTION BEFORE USE 10 INSTRUCTIONS ON REMOTE CONTROLLER 11...

Page 3: ...using massage chair in a very cold place please don t increase indoor temperature too quick but by increased gradually If you re moving massage chair from very cold place to warmer place you should wa...

Page 4: ...r hasn t been used for a long time we recommend to ask mechanist to recheck it again BODY POSTURE HAVE TO KEEP UPRIGHT WHILE MASSAING If you prefer a gentle massaging you can put a blanket or towel on...

Page 5: ...AGE CHAIR Model No TC 626 Input Voltage Refer to products label Power Consumption Refer to products label Frequency Refer to products label Net Weight 95kgs Material PU Unit Set Carton size 1400 L 830...

Page 6: ...PRODUCT STRUCTURE MAIN PART OF MASSAGE CHAIR FRONT P 5 Head Pad Back Rest Controller Seat Pad Arm Rest Back Pad Shoulder Set Foot Rest Castors...

Page 7: ...MAIN PART OF MASSAGE CHAIR BACK P 6 Fix part of back pad and head pad removable Back Cover Controller Interface Power switch Fuse Power wire...

Page 8: ...re B Assembly the side board a Remove the side board package box and take out the side board b Connect the air hosts of side board and one side of the frame Please notice of inserting the hosts to the...

Page 9: ...nd to the hold on side board Tighten the 4 screws with Phillips screwdriver d Take the controller from the foot stand Remove the plastic bag and put it on the stand D Make sure there s enough room for...

Page 10: ...ace Please place massage chair away from AV TV and radio for at least 1 M to prevent interference of signal E Move and place massage chair As picture shown on left side please lift up the foot rest fi...

Page 11: ...urrounding have no obstacles Connect the electricity power Turn on the power switch which located on the rear cover of the massage chair Adjust both the position of head cushion s bottom portion and e...

Page 12: ...RONT SIDE POWER PAUSE DISPLAY WINDOW SEATREST PORTION ZERO GRAVITY Timing adjustment AUTO PROGRAMS FOOTREST ADJUSTMENT POSITION ADJUSTMENT WIDTH ADJUSTMENT SPEED ADJUSTMENT AIR PRESSURE MASSAGE AREA M...

Page 13: ...rom the bottom of the waist all the way to the buttocks area ZERO GRAVITY 1st time to push this button then Back and footrest synchronously lean to 1st Zero G stage position 2nd time to push this butt...

Page 14: ...rence you only need to push any manual program buttons to choose your favorite massage styles Adjust the massage roller s and position button And keeping press on AREA button until a suitable location...

Page 15: ...air backrest footrest ajustment display 4 zero gravity position ajustment display 5 remain time display 6 pause status display 7 massage roller width display 8 spot area massage display 9 massage roll...

Page 16: ...e it s clear around the chiar in advance 2 After massage chair stop all the actions please put controller on the holder 3 Please press the power button to the turn off on the massage chair if you don...

Page 17: ...pply and remove the plug from the wall socket Use only a dry cloth to clean the machine to prevent water seepage Use only a dry cloth to clean the machine to prevent water seepage Plastic part tube an...

Page 18: ...e following situations happened It s normal when operation sounds occured Wheel and cloth rubbing sounded Motor sounded when loading Massage roller sounded Tapping sounded Seating sounded Motor sounde...

Page 19: ...will stop working due to the safety concerned Turn off the machine and turn on it again after 10 seconds DO NOT lie on the chair too hard Please make sure that the plug had plug in the socket properl...

Reviews: