TF5/TF3/TF1/TF-RACK/NY64-D Firmware Update Guide

 

 

8

 

3-2. Connect the Dante [PRIMARY] connector of the NY64-D card to the Ethernet connector on the 

computer using an Ethernet cable. 

Be sure to directly connect the computer and the NY64-D, and do not connect any other Dante device to 
the computer. 

 

3-3. Execute the Dante Firmware Update Manager, and update the NY64-D firmware. 

Follow step 5 (“Using  the Dante Firmware Update Manager”) of the Dante Firmware Update Manager 
User Guide to update. 
Use the firmware update file “

FWUpdate_NY64-D_vxxxxx_swyyy.dnt” (xxxxx, yyy: firmware version)

 

 

NOTICE: 
Be sure to ensure compatibility of the update files with NY64-D. If update files other than NY64-D are 
applied, the device will become inoperable. In general, do not check the [Override Device Matching] 
option. If this option is left unchecked, only devices that support the file can be selected, ensuring that 
updating the device with invalid or wrong files is prevented. 

 

NOTE 
If  the  update is not completed after 5 minutes, or an  update failure indication appears, click X at the 
upper right corner of the Dante Firmware Update Manager to exit the program 

without turning the TF 

series power off

, and restart the procedure from the step 3-3. If the  update still fails, follow the 

instructions stated in “If the NY64-D update failed” (page 9) to perform the recovery operation. 

 

3-4. Restart the TF series. 

 
The firmware update is now complete. 
 

Summary of Contents for TF Series

Page 1: ...while the update is in progress If the update fails and the device still does not operate correctly even after you execute the update once again please contact your Yamaha dealer Yamaha Corporation o...

Page 2: ...matted in FAT32 For the formatting procedure refer to TF5 TF3 TF1 TF RACK Reference Manual For formatting in a computer refer to documentations supplied with the computer or its OS The TF series firmw...

Page 3: ...extracted from the downloaded zip file to the root directory of the USB flash drive Make sure that no other files except those relevant to the TF series and NY64 D firmware are copied to the root dir...

Page 4: ...g the firmware CAUTION DO NOT OPERATE ANY CONTROL OF THE CONSOLE SWITCHES KNOBS FADERS ETC WHILE UPDATING THE FIRMWARE TF series firmware is transferred lasting about two minutes After finishing the f...

Page 5: ...ched 100 completion Done or a message prompting to reboot the TF series appears these are all normal During the update process the display or the LED indicator may turn off This is normal 8 If you nee...

Page 6: ...P ABOUT window The firmware update is now complete NOTE Some firmware versions have new default Presets for Scene or Library To load the new Presets the Initialize All Memories operation is required R...

Page 7: ...irmware_Update_Manager vX Xen pdf vX X version of the user guide http www yamahaproaudio com Update procedure sequence Make sure to perform the update in the following sequence If you plan to update m...

Page 8: ...tibility of the update files with NY64 D If update files other than NY64 D are applied the device will become inoperable In general do not check the Override Device Matching option If this option is l...

Page 9: ...not boot in the failsafe mode you will need to recover the system by a different procedure see Updating the NY64 D firmware by computer via the Dante Firmware Update Manager Confirming the NY64 D firm...

Page 10: ...uter using an Ethernet cable In some cases an error may occur during recovery if you are going through a network switch Connect the computer with the NY64 D in a one to one connection 4 Turn on the po...

Page 11: ...e NY64 D from the Dante network 3 Connect the Dante PRIMARY connector of the NY64 D to the Ethernet connector on the computer using an Ethernet cable In some cases an error may occur during recovery i...

Page 12: ...TF5 TF3 TF1 TF RACK NY64 D Firmware Update Guide 12 Manual Development Department 2015 Yamaha Corporation Published 1 2017 YJ D0...

Reviews: