< Table 1 - 4 >
MIDI Parameter Change table ( MULTI EQ )
Address
Size
Data
Parameter
Description
Default value
(H)
(H)
(H)
(H)
02
40
00
1
00 - 04
EQ TYPE
flat, jazz, pops, rock, classic
00
01
1
34 - 4C
EQ GAIN1
-12...0...+12[dB]
40(depends on EQ type)
02
1
04 - 28
EQ FREQUENCY1
32...2.0k[Hz]
0C(
″
)
03
1
01 - 78
EQ Q1
0.1...12.0
07(
″
)
04
1
00 - 01
EQ SHAPE1
shelving , peaking
00(
″
)
05
1
34 - 4C
EQ GAIN2
-12...0...+12[dB]
40(
″
)
06
1
0E - 36
EQ FREQUENCY2
100...10.0k[Hz]
1C(
″
)
07
1
01 - 78
EQ Q2
0.1...12.0
07(
″
)
08
1
NOT USED
—
09
1
34 - 4C
EQ GAIN3
-12...0...+12[dB]
40(
″
)
0A
1
0E - 36
EQ FREQUENCY3
100...10.0k[Hz]
22(
″
)
0B
1
01 - 78
EQ Q3
0.1...12.0
07(
″
)
0C
1
NOT USED
—
0D
1
34 - 4C
EQ GAIN4
-12...0...+12[dB]
40(
″
)
0E
1
0E - 36
EQ FREQUENCY4
100...10.0k[Hz]
2E(
″
)
0F
1
01 - 78
EQ Q4
0.1...12.0
07(
″
)
10
1
NOT USED
—
11
1
34 - 4C
EQ GAIN5
-12...0...+12[dB]
40(
″
)
12
1
1C - 3A
EQ FREQUENCY5
0.5k...16.0k[Hz]
34(
″
)
13
1
01 - 78
EQ Q5
0.1...12.0
07(
″
)
14
1
00 - 01
EQ SHAPE5
shelving , peaking
00(
″
)
TOTAL SIZE
15
< Table 1 - 5 >
MIDI Parameter Change table ( EFFECT 2)
Address
Size
Data
Parameter
Description
Default value
(H)
(H)
(H)
(H)
03
00
00
2
00 - 7F
INSERTION EFFECT1 TYPE MSB
refer to Effect Program List
49(=DISTORTION)
00 - 7F
INSERTION EFFECT1 TYPE LSB
″
00
02
1
00 - 7F
INSERTION EFFECT1 PARAMETER1
″
28(depends on insertion effect1 type)
03
1
00 - 7F
INSERTION EFFECT1 PARAMETER2
″
14(
″
)
04
1
00 - 7F
INSERTION EFFECT1 PARAMETER3
″
48(
″
)
05
1
00 - 7F
INSERTION EFFECT1 PARAMETER4
″
35(
″
)
06
1
00 - 7F
INSERTION EFFECT1 PARAMETER5
″
40(
″
)
07
1
00 - 7F
INSERTION EFFECT1 PARAMETER6
″
00(
″
)
08
1
00 - 7F
INSERTION EFFECT1 PARAMETER7
″
2B(
″
)
09
1
00 - 7F
INSERTION EFFECT1 PARAMETER8
″
4A(
″
)
0A
1
00 - 7F
INSERTION EFFECT1 PARAMETER9
″
0A(
″
)
0B
1
00 - 7F
INSERTION EFFECT1 PARAMETER10
″
7F(
″
)
0C
1
00 - 7F
INSERTION EFFECT1 PART NUMBER
Part1...32(0...31)
7F
Audio1~14(64~67)
OFF(127)
0D
1
00 - 7F
MW INSERTION CONTROL DEPTH
-64...0...+63
40
0E
1
00 - 7F
BEND INSERTION CONTROL DEPTH
-64...0...+63
40
0F
1
00 - 7F
CAT INSERTION CONTROL DEPTH
-64...0...+63
40
10
1
00 - 7F
AC1 INSERTION CONTROL DEPTH
-64...0...+63
40
11
1
00 - 7F
AC2 INSERTION CONTROL DEPTH
-64...0...+63
40
TOTAL SIZE
12
20
1
00 - 7F
INSERTION EFFECT1 PARAMETER11
refer to Effect Parameter List
78(depends on insertion effect1 type)
21
1
00 - 7F
INSERTION EFFECT1 PARAMETER12
″
00(
″
)
22
1
00 - 7F
INSERTION EFFECT1 PARAMETER13
″
00(
″
)
23
1
00 - 7F
INSERTION EFFECT1 PARAMETER14
″
00(
″
)
24
1
00 - 7F
INSERTION EFFECT1 PARAMETER15
″
00(
″
)
25
1
00 - 7F
INSERTION EFFECT1 PARAMETER16
″
00(
″
)
TOTAL SIZE
06
30
2
00 - 7F
INSERTION EFFECT1 PARAMETER1 MSB
refer to Effect Parameter List
00(depends on insertion effect1 type)
00 - 7F
INSERTION EFFECT1 PARAMETER1 LSB
″
28(
″
)
32
2
00 - 7F
INSERTION EFFECT1 PARAMETER2 MSB
″
00(
″
)
00 - 7F
INSERTION EFFECT1 PARAMETER2 LSB
″
14(
″
)
34
2
00 - 7F
INSERTION EFFECT1 PARAMETER3 MSB
″
00(
″
)
00 - 7F
INSERTION EFFECT1 PARAMETER3 LSB
″
48(
″
)
36
2
00 - 7F
INSERTION EFFECT1 PARAMETER4 MSB
″
00(
″
)
00 - 7F
INSERTION EFFECT1 PARAMETER4 LSB
″
35(
″
)
38
2
00 - 7F
INSERTION EFFECT1 PARAMETER5 MSB
″
00(
″
)
00 - 7F
INSERTION EFFECT1 PARAMETER5 LSB
″
40(
″
)
3A
2
00 - 7F
INSERTION EFFECT1 PARAMETER6 MSB
″
00(
″
)
00 - 7F
INSERTION EFFECT1 PARAMETER6 LSB
″
00(
″
)
3C
2
00 - 7F
INSERTION EFFECT1 PARAMETER7 MSB
″
00(
″
)
00 - 7F
INSERTION EFFECT1 PARAMETER7 LSB
″
2B(
″
)
3E
2
00 - 7F
INSERTION EFFECT1 PARAMETER8 MSB
″
00(
″
)
00 - 7F
INSERTION EFFECT1 PARAMETER8 LSB
″
4A(
″
)
40
2
00 - 7F
INSERTION EFFECT1 PARAMETER9 MSB
″
00(
″
)
00 - 7F
INSERTION EFFECT1 PARAMETER9 LSB
″
0A(
″
)
42
2
00 - 7F
INSERTION EFFECT1 PARAMETER10 MSB
″
00(
″
)
00 - 7F
INSERTION EFFECT1 PARAMETER10 LSB
″
7F(
″
)
TOTAL SIZE
14
When using an EFFECT TYPE which does not require the MSB, parameters of addresses 02...0B are received, and parameters of addresses 30...42 are not
received.
When using an EFFECT TYPE which requires the MSB, parameters of addresses 30...42 are received, and parameters of addresses 02...0B are not received.
Bulk data which includes the EFFECT TYPE is always transmitted with the parameters of addresses 02...0B, but in the case of an EFFECT TYPE which requires
the MSB, parameters of addresses 02...0B are not received even for bulk reception.
77