4. Remote Control of AD824 or AD8HR Units
To remote control the Head-Amp settings of these units. Select HA as the REMOTE
FUNCTION in the REMOTE page of the SETUP menu. Then select which slots are
used for which units (the Unit ID is displayed on the front panel of the remote AD
units). Assign one of the ENCODER MODE ASSIGN keys to HA Gain so the input
Gain can be controlled from the Channel Encoders. PHANTOM POWER can be
controlled from the HA CTRL page in the PHASE/INSERT menu.
5. SCENE MEMORY Auto Update
In the PREFERENCES1 page of the SETUP menu, the Scene MEM Auto Update
option can be found. When this is switched on, the last mixing settings are
memorised just before the next Scene is recalled.
Then when a previous Scene is recalled, its last settings are recalled first. Press
RECALL again to access the original scene settings. So two memories for each
scene are kept: the original settings, and the last settings.
6. Return to Current Scene
When scrolling through the SCENE MEMORY list, it is easy to forget which is the
current Scene. To return to displaying the current Scene, press both SCENE UP
and DOWN keys simultaneously.