![Yamaha Silent Piano SG Series Maintenance Handbook Download Page 9](http://html2.mh-extra.com/html/yamaha/silent-piano-sg-series/silent-piano-sg-series_maintenance-handbook_4772507009.webp)
6.Maintenance and Test Modes
1)Maintenance mode (measurement mode)
Key sensor measurement “All-key measurement” / “1-key measurement” procedure
No.
1
2
3
4
5
6
7
End value measurement
Flash RAM writing
Depress the shift pedal.
→
The writing will be
completed in about 10 sec,
then 76C will sound.
“All-key measurement”
Measurement item
Press 1 to 88 keys lightly one
by one to the end position.
Depress the damper pedal.
→
A tone will be sounded at
regular 2 sec intervals.
Power OFF
Depress the damper pedal.
→
Three successive tones
will be sounded at regular 1
sec intervals.
Rest value measurement
Confirm that key is in the rest
position.
Start of rest value
measurement
Depress the damper pedal.
→
Two successive tones will
be sounded at regular 1 sec
intervals.
Start-up
Complete
End value registration
Confirm that key is in the rest
position.
Depress the damper pedal.
→
Three successive tones will
be sounded at regular 1 sec
intervals.
Press 1 to 88 keys lightly one by
one to the end position.
Depress the damper pedal.
→
A tone will be sounded at
regular 2 sec intervals.
Depress the shift pedal.
→
The writing will be completed
in about 10 sec, then 76C will
sound.
Power OFF
10F#+12G#+14A#+ power ON
(release keys in 2 sec.)
→
A tone will be sounded at
regular 2 sec intervals.
(Waiting mode)
→
Wait for about 30sec.
Rest value registration
“1-key measurement”
9F+11G+ power ON (release keys
in 2 sec.)
→
Two successive tones will be
sounded at regular 1 sec intervals.
(Key selection status) *1
Press 1 key to be measured.
→
The tone will change to the
tone of the key to be measured. *2
Maintenance mode is a program for adjusting the key sensor and damper pedal sensor.
Measurement by maintenance mode shall be required in the following cases;
・
If the detection position is out of standard, when checked in the test mode.
・
When replacing the key sensor rail, damper pedal sensor and DM sheet, etc.
Note 1: If the tone is consonant (“do”, “mi”, “sol” and “do”), the writing has already been done in the
table.
If the tone is dissonant, the writing has not been done in the table.
Note 2: One key measurement requires the same procedure as for the measurement of all keys.
If more than one key is to be measured, repeat the steps 3 through 6 and then proceed to step 7).
[Key sensor measurement]
For key sensor measurement, there is “All-key measurement” to rewrite the measurement of all
keys and “1-key measurement” to rewrite only a designated key.
9