RX-V990
CONTENTS OF DIAG. OPERATIONS
• DIAG. MENU can be selected by pressing the PRESET
STATIONS
key of the front panel or PROGRAM key of
the remote control transmitter.
• Each DIAG. MENU has a SUB-MENU.
Every time the
same key, PRESET STATIONS key of the front panel or
PROGRAM
key of the remote
control
transmitter
is
pressed,
another SUB-MENU
is selected.
• While the diagnostic
mode is set, function of power on/
off, selecting
an input source, adjusting master volume
and effect level are available.
• The contents of each DIAG. MENU are as follows.
No.
DIAG. Menu
Sub Menu
1
MAIN BYPASS
EFFECT LEVEL 60 (-10dS)/80 (OdS)
2
FRONT RAM THR
EFFECT LEVEL 60 (-10dS)/80 (OdS)
3
MAIN DSP THR
EFFECT LEVEL
100 (+10dS)/60 (-10dS)/80 (OdS)
4
EFFECT OFF/DISP
EFFECT OFF/DISPLAY CHECK
5
MANUAL TEST
TEST: LEFT/CENTER/RIGHT/SUR
6
PRO LOGIC
CENTERNORMAUCENTER
WIDE/CENTER
PHANTOM/BYPASS/CINE
EO.ON (Note1)
7
FACTORY PRESET
KEEP DATNFACTORY
PRESET
8
AD CHECK MODE
KEY AD
&
OTHER AD CHECK
9
EXIT (Note 2)
-
Note 1: CI N E EO ON appears
but such function
is not
provided.
Note 2: No.9
menu item is available
only through
the
remote control.
5
FL DISPLAY
When the DIAGNOSTIC
mode is set, the initial display
appears on the FL display followed by the DIAGNOSTIC
display (No.1).
The initial display can be redisplayed by pressing the AlB/
C/D/E key (but not when performing
AD check by using
DIAG. No.8).
• Components
of initial display
(Example)
[3= ~CJ
40
t
t
RXV990U
**
t
t
Protection
AD
Message
value
Model
&
ROM
Market
version
[Protection
message]
When the protection function activated, the protection mes-
sage is displayed and the power is turned off.
Instantly ~ "1 I"
After about 0.5 seconds ~ "2 PS"
After about 2 seconds -
"3 DC"
Correct the faulty part according to the protection message.
Protectionmessage
Cause
1 I
An abnormalcurrentflowedto the poweramplifier.
2 PS
Abnormalconditionoccurredin the powersection.
3 DC
DCis detectedin the outputof the poweramplifier.
[AD value to Model
&
Market relation]
AD value (+3) Model& Market
Remarks
10
RXV990 R
**
R : General model
40
RXV990 U"
UC : USA
&
Canadian models
40
RXV990 A
**
A : Australian model
70
RXV990 L"
G : European model
• Components
of DIAGNOSTIC
display
1
DIAG.tmenu
CD
+
MAIN BYP 60
operat{on display
Input source
No.
*Supplement
When in the DIAG. mode, lighting of all segments
of
the tuning meter for catalogue
photographing
can be
reserved by using the EFFECT key. (Do not use this
function as it is not intended for servicing.)
With such reservation
made, all segments of the tun-
ing meter light when the tuner function is selected in
the normal mode. (This reservation
is effective once
only at the next POWER ON. After that, normal meter
operation is provided.)
Content
FL display
Reservation of full scale
T-METER ON
Reservation of normal
T-METER OFF
Summary of Contents for RX-V990