RX-V730/RX-V730RDS/RX-V630/RX-V630RDS
HTR-5560/HTR-5560RDS/DSP-AX630/DSP-AX630SE
RX-V730/RX-V730RDS/RX-V630/RX-V630RDS
HTR-5560/HTR-5560RDS/DSP-AX630/DSP-AX630SE
22
Cause:
The voltage in the power supply section is
abnormal.
Supplementary information:
The abnormal voltage is
displayed in % based on 5V as 100%.
Turning on the power without correcting the abnormality
will cause the protection function to work 1 second later
and the power supply will be shut off.
When there is a history of protection
function due to abnormal voltage in
the power supply section
電源部の電圧異常によるプロテク
ション履歴がある場合
Version (1 alphabet)
バージョン(英1文字)
Voltage display in %
電圧の%表示
When there is a history of protection
function due to abnormal DC output
DC出力異常によるプロテクション
履歴がある場合
Version (1 alphabet)
バージョン(英1文字)
Cause:
DC output of the power amplifier is abnormal.
Turning on the power without correcting the abnormality
will cause the protection function to work 3 seconds later
and the power supply will be shut off.
原因: パワーアンプのDC出力が異常。
異常状態のままパワーオンすると、3秒後にプロテクショ
ンがかかり、電源が切れます。
原因: 電源部の電圧が異常。
補足: 異常時の電圧の状態を、5Vを100%とした値で%表
示します。
異常状態のままパワーオンすると、1秒後にプロテクショ
ンがかかり、電源が切れます。
Cause:
An excessive current flowed through the power
amplifier.
Supplementary information:
As current of the power
transistor is detected, the abnormal channel can be
identified by checking the current detect transistor.
Turning on the power without correcting the abnormality
will cause the protection function to work immediately and
the power supply will instantly be shut off.
Note)
• Applying the power to a unit without correcting the
abnormality can be dangerous and cause additional
circuit damage.
• The output transistors in each amplifier channel
should be checked for damage before applying any
power.
• Amplifier current should be monitored by measuring
across the emitter resistors for each channel.
原因: パワーアンプに過電流が流れた。
補足: パワートランジスタの電流を検出していますので、
電流検出トランジスタをチェックすれば異常チャン
ネルが特定できます。
異常状態のままパワーオンすると、瞬時にプロテクション
がかかり、すぐに電源が切れます。