AMP ADJUSTMENT
●
CONFIRMATION OF IDLING CURRENT
1. Right after the power is turned on, confirm that the volt-
age across the terminals of R111–R135 (L ch) and R112–
R136 (R ch) are between 0.1mV to 10.0mV.
2. If the measured voltage exceeds 10.0mV, open (cut off)
R175 (L ch), R176 (R ch) and reconfirm the voltage.
3. Confirm that the voltage is between 0.20mV and 15.0mV
after 60 minutes.
R135
R175
R176
R111
R112
R136
R111
R112
R135
R136
Cut
R175 (L ch)
R176 (R ch)
0.1mV–10mV
(L ch)
0.1mV–10mV
(R ch)