CS-R5 Owner’s Manual
23
Connecting to power sources
1.
Turn off both power switches A and B on the
unit.
2.
Connect one of the supplied power cords to
AC IN connector (A), and the other to AC IN
connector (B).
3.
Connect the other end of each power cord to
an AC outlet of a different power source.
NOTE
• Follow this procedure in reverse order when disconnecting the
power cords.
• To disconnect each power cord, remove it while pressing the
latch on the plug.
Warning
Use only the supplied AC power cords. Using other cords may
lead to overheating or electric shock.
Caution
Be sure to turn off the power to the unit before connecting or
disconnecting the power cords.
Shutting down the power to
the unit
Before you turn off the power to the control surface,
Yamaha recommends that you store the current status to
scene memory.
If you change the connection status of the components
after the power is turned off, some settings, such as
patching, may be altered when you turn the power on
again. For more information on storing a scene, please
refer to the RIVAGE PM series Operation Manual.
NOTICE
If you turn off the power to the control surface without following
the shutdown procedure, data inside the built-in storage may be
damaged. Be sure to perform the shutdown procedure to turn off
the power to the control surface.
1.
Press the [SYSTEM] key (see
4
for two seconds or longer.
A message will ask you to confirm the shutdown
operation.
2.
To turn the power off, press the OK button. To
cancel shutdown, press the CANCEL button.
3.
Wait until the LEDs on the panel turn off and
the touch screens go dark.
4.
Turn off both power switches A and B on the
rear panel.
NOTICE
• If you plan to turn on the power to the control surface again,
wait at least five seconds before switching the power on.
Otherwise, the unit may malfunction.
• Even when the power switches are turned off, a small amount
of current still flows through the unit. If you plan not to use the
unit for a long period of time, remove the power cords from the
AC outlets.
Power Supply /
Shutdown