Maintenance screen
Reference Manual
TF Series
- 81 -
Fader Calibration screen (TF5/TF3/TF1)
In some usage environments, discrepancies may occur in the motion of the motor faders. You
can use this screen to correct these discrepancies
1
START button
Starts the calibration.
Touch to display the confirmation message. Touch the OK button to perform the
operation.
2
Cancel button
Stops the calibration.
3
Apply button
Applies the settings and exits.
ձ
ղ
ճ
Calibrating the faders
1.
Press the [SEL] key on the top panel that corresponds to the fader you want to
calibrate.
2.
Touch the START button on the FADER CALIBRATION MODE screen.
3.
Touch the OK button when the confirmation message is displayed.
4.
When calibration has finished, touch the APPLY button.
5.
Touch the Exit button in the maintenance menu and start up the console as usual.
If a fader must be calibrated again
If a fader must be calibrated again, the [ON] or [CUE] key of the corresponding fader will flash.
Use the following procedure to recalibrate.
1.
When the message "Found faders requiring adjustment. Please calibrate faders again."
is displayed, touch the Close button to close the popup.
2.
Touch the Apply button displayed on the screen.
The [SEL] key of the fader that was flashing begins to flash.
3.
Slide the corresponding fader to the highest and lowest positions several times.
Make sure the fader's slide action is smooth and not getting stuck.
4.
Perform the procedure described in "Calibrating the faders" beginning at step
2
.
If you perform this procedure multiple times and the popup message is still displayed, contact
your Yamaha dealer.
NOTE
• This feature automatically calibrates the specified fader (channel strip or master section fader).
• When calibration is complete, you can continue to use other maintenance features without exiting.