FCC INFORMATION (U.S.A.)

1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! This product, when installed as indicated in the instructions contained in this manual, meets FCC 

requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product.

2. IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. Cable/s supplied with this product MUST 

be used. Follow all installation instructions. Failure to follow instructions could void your FCC authorization to use this product in the USA.

3. NOTE: This product has been tested and found to comply with the requirements listed in FCC Regulations, Part 15 for Class “B” digital devices. Compliance with 

these requirements provides a reasonable level of assurance that your use of this product in a residential environment will not result in harmful interference with 
other electronic devices. This equipment generates/uses radio frequencies and, if not installed and used according to the instructions found in the users manual, may 
cause interference harmful to the operation of other electronic devices. Compliance with FCC regulations does not guarantee that interference will not occur in all 
installations. If this product is found to be the source of interference, which can be determined by turning the unit “OFF” and “ON”, please try to eliminate the 
problem by using one of the following measures: Relocate either this product or the device that is being affected by the interference. Utilize power outlets that are on 
different branch (circuit breaker or fuse) circuits or install AC line filter/s. In the case of radio or TV interference, relocate/reorient the antenna. If the antenna lead-in 
is 300 ohm ribbon lead, change the lead-in to coaxial type cable. If these corrective measures do not produce satisfactory results, please contact the local retailer 
authorized to distribute this type of product. If you can not locate the appropriate retailer, please contact Yamaha Corporation of America, Electronic Service 
Division, 6600 Orangethorpe Ave, Buena Park, CA 90620

The above statements apply ONLY to those products distributed by Yamaha Corporation of America or its subsidiaries.

WARNING: THIS APPARATUS MUST BE EARTHED

IMPORTANT

THE WIRES IN THIS MAINS LEAD ARE COLOURED IN 
ACCORDANCE WITH THE FOLLOWING CODE:

          GREEN-AND-YELLOW :      EARTH

          BLUE :                                     NEUTRAL

          BROWN :                                LIVE

As the colours of the wires in the mains lead of this apparatus may 
not correspond with the coloured markings identifying the terminals in 
your plug, proceed as follows:

The wire which is coloured GREEN and YELLOW must be 
connected to the terminal in the plug which is marked by the letter E 
or by the safety earth symbol        or coloured GREEN and YELLOW.

The wire which is coloured BLUE must be connected to the terminal 
which is marked with the letter N or coloured BLACK.

The wire which is coloured BROWN must be connected to the 
terminal which is marked with the letter L or coloured RED.

* This applies only to products distributed by YAMAHA KEMBLE 

MUSIC (U.K.) LTD.

Summary of Contents for PW3000M

Page 1: ...POWER SUPPLY Owner s Manual Mode d emploi Bedienungsanleitung M ...

Page 2: ...ng measures Relocate either this product or the device that is being affected by the interference Utilize power outlets that are on different branch circuit breaker or fuse circuits or install AC line filter s In the case of radio or TV interference relocate reorient the antenna If the antenna lead in is 300 ohm ribbon lead change the lead in to coaxial type cable If these corrective measures do n...

Page 3: ...ee air space around the power supply unit If the power supply unit is to be rack mounted leave at least 10 cm free above the top panel and behind the rear panel When the power supply unit is in use remove the rear of the rack or open its ventilation slots to prevent overheating which could be a fire hazard Do not try to modify the power supply unit This could be a fire and electrical shock hazard ...

Page 4: ...sis of the other device D DC OUTPUT connector Connect this connector to the M3000 to supply power to it E DC PARALLEL INPUT connector This connector allows two PW3000M units to be con nected in parallel As shown in the following diagram use the included parallel connection cable to make connections In this case the two PW3000M units will each supply 50 of the power in normal operation Even in the ...

Page 5: ...Power Consumptions USA and Canada 400 W 540 VA Europe 380 W Others 380 W Dimension W x H x D 480mm x 103 5mm x 455mm Weight 15kg Pin No Signal name Power supply connector 1 Power supply remote 2 15 V 3 15 V GND 4 48 V GND 5 15 V 6 12 V 7 12V GND power supply remote 8 Power supply remote 9 48 V 10 FRAME GND DC OUTPUT DC PARALLEL INPUT 1 2 3 8 9 10 5 4 6 7 3 2 1 10 9 8 6 7 5 4 D 455 W 480 88 H 103 5...