PC3301N
PC2001N
1/8 power is typical of program material with occasional clipping. Refer to these
fi
gures for most applications.
1/3 power represents program material with extremely heavy clipping.
Test signal: Pink Noise, bandwidth limited from 22Hz to 22kHz
1W = 0.860kcal/h, 1BTU = 0.252kcal
Note that Line Voltage [V] x Line Current [A] = [VA], not equals to [W].
Inrush current
PC9501N: 7A (100V), 8A (120V), 16A (240V)
PC6501N, PC4801N, PC3301N, PC2001N: 10A (100V), 12A (120V), 23A (240V)
Line Current (A)
Power (W)
Thermal Dissipation
100/120V
230/240V
In
Out
Dissipated
Btu/h
kcal/h
standby
0.08
0.04
5
0
5
17
4
idle
1.0
0.5
40
0
40
137
34
1/8 power
8
Ω
/ch
2.7
1.5
189
88
102
348
88
4
Ω
/ch
5.0
2.7
357
150
207
707
178
1/3 power
8
Ω
/ch
6.4
3.5
459
233
226
771
194
4
Ω
/ch
12.0
6.6
866
400
466
1590
401
Line Current (A)
Power (W)
Thermal Dissipation
100/120V
230/240V
In
Out
Dissipated
Btu/h
kcal/h
standby
0.08
0.04
5
0
5
17
4
idle
1.0
0.5
40
0
40
137
34
1/8 power
8
Ω
/ch
1.9
1.1
134
58
77
261
66
4
Ω
/ch
3.1
1.7
224
88
137
467
118
1/3 power
8
Ω
/ch
4.5
2.5
325
153
172
586
148
4
Ω
/ch
7.6
4.2
544
233
311
1060
267
IMPORTANT NOTICE FOR THE UNITED KINGDOM
Connecting the Plug and Cord
WARNING:
THIS APPARATUS MUST BE EARTHED
IMPORTANT. The wires in this mains lead are coloured in accordance
with the following code:
GREEN-AND-YELLOW : EARTH
BLUE
: NEUTRAL
BROWN
: LIVE
As the colours of the wires in the mains lead of this apparatus may not
correspond with the coloured markings identifying the terminals in
your plug proceed as follows:
The wire which is coloured GREEN-and-YELLOW must be connected
to the terminal in the plug which is marked by the letter E or by the
safety earth symbol
or colored GREEN or GREEN-and-YELLOW.
The wire which is coloured BLUE must be connected to the terminal
which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the termi-
nal which is marked with the letter L or coloured RED.
• This applies only to products distributed by Yamaha-Kemble Music (U.K.) Ltd.
(3 wires)
This mark indicates a dangerous electrically live terminal.
When connecting an external wire to this terminal, it is necessary
either to have “a person who have received appropriate
guidance on handling” make the connection or to use leads or a
cord that have been manufactured in such a way that the
connection can be made simply and without problem.