MX49/MX61 Reference Manual
68
The Remote settings are made in this display. If you press [UTILITY] in the Remote mode, only this display will be called
up.
Utility Job
Using Quick Setup can instantly call up appropriate sequencer-related panel settings by selecting convenient preset
setups, allowing you to simultaneously and instantly set a variety of important sequencer-related parameters. Press
[ENTER] after setting to execute the setup. The settings for each preset setup are listed below.
Settings:
St Alone (Stand Alone), DAW Rec (DAW Record), Arp Rec (Arpeggio Record)
Remote
Parameter
Description
DAW Select
Determines the DAW software to be controlled by the MX49/MX61. Simply selecting a DAW type calls up the
appropriate Remote settings automatically.
Settings:
Cubase, LogicPro, DigiPerf, SONAR
PrgChgMode
(Program Change
Mode)
Determines what messages will be transmitted to the computer when you operate the [INC/YES]/[DEC/NO]
buttons or [DATA] dial. When “PC” is selected, Program Change messages will be transmitted via MIDI Port
1. When “remote” is selected, Remote Control messages will be transmitted via MIDI Port 2. When “auto” is
selected, this automatically switches whether Program Change messages will be transmitted via MIDI Port 1
or Remote Control messages will be transmitted via MIDI Port 2 according to the DAW software controlled in
the Remote mode. The Remote Control messages can be transmitted only when the VSTi in Cubase is
controlled in the Remote mode.
Settings:
remote, PC, auto
NOTE
This parameter is fixed to “PC” when “DAW Select” is set to something other than “Cubase.”
Operation
Press [UTILITY]
Press [JOB]
Select desired display for editing with the Cursor [
u
]/[
d
] buttons
Press [E
N
TER]
Edit parameters in selected display
Press [E
N
TER]
QuickSetup
St Alone
DAW Rec
Arp Rec
DirectMonitor (Direct Monitor Switch)
on
on
on
LocalCtrl (Local Control)
on
off
on
MIDI Sync
internal
auto
auto
Clock Out
on
off
off
MIDI Out (Arpeggio MIDI Output Switch)
on
off
on