15
add-
4. System Exclusive Messages
4.1 Parameter Change
The MU5 receives and responds to the following parameter change messages:
• Universal Real Time Message
Master Volume
• Universal Non Real Time Message
General MIDI Mode On
• Yamaha GM Exclusive Message
MIDI Master Tuning
• Parameter Changes Specific to MU5
System Data parameter change
Multi Part data parameter change
Reset All Parameters
System Parameter
Multi Parameter
All Parameter Reset
• Parameter Changes Specific to TG100
4.2 Universal Real Time Message
4.2.1 Master Volume
11110000 F0
= Exclusive status
01111111 7F
= Universal real time
01111111 7F
= ID of target device
00000100 04
= Sub-ID #1=Device control message
00000001 01
= Sub-ID #2=Master volume
0sssssss
SS
= Volume LSB
0 t t t t t t t
TT
= Volume MSB
11110111 F7
= End of exclusive
or
11110000 F0
= Exclusive status
01111111 7F
= Universal real time
0xxxnnnn XN
= Device number, xxx = Not used
00000100 04
= Sub-ID #1=Device control message
00000001 01
= Sub-ID #2=Master volume
0sssssss
SS
= Volume LSB
0 t t t t t t t
TT
= Volume MSB
11110111 F7
= End of exclusive
Following reception of the above parameters, the Volume MSB affects the Master
Volume of the System Parameters.