Edit
MODX Reference Manual
165
Reference
Common Motion Seq Shape (Common Motion Sequencer Pulse Shape)
Determines the Pulse Shape of the Motion Sequencer for the entire Performance. This changes the step
curve shape of the sequence.
This is the offset value for the Part Motion Seq Pulse Shape, which is also the offset value for the Lane
Pulse Shape. This results in that both of the Common and Part MS Pulse Shapes offset the Pulse Shape
setting for the parameter in the Lane (only when “MS FX” is set to on for the Lane and “Control” is set to on
for the parameter).
Settings:
-100 – +100
Common Motion Seq Smooth (Common Motion Sequencer Smoothness)
Determines the Smoothness of the Motion Sequencer for the entire Performance. “Smoothness” is the
degree to which the time of the Motion Sequence is smoothly changed.
This is the offset value for the Part Motion Seq Smoothness, which is also the offset value for the Lane
Smoothness. This results in that both of the Common and Part MS Smoothnesses offset the Smoothness
setting for the parameter in the Lane (only when “MS FX” is set to on for the Lane).
Settings:
-64 – +63
Common Motion Seq Random (Common Motion Sequencer Random)
Determines the Random of the Motion Sequencer for the entire Performance. “Random” is the degree to
which the Step Value of the Sequence is randomly changed.
This is the offset value for the Part Motion Seq Random when “MS FX” is set to on for the Lane.
Settings:
-64 – +63
Random (A/D Part Motion Sequencer Random)
Determines the degree of random change in the Step Value of the Motion Sequence for the A/D Part is. For
details about “Random,” see “Quick Edit” on
.
Settings:
0–127
Sync Part (Motion Sequencer Sync Part)
Determines the Part for synchronizing to the Motion Sequencer. The Motion Sequencer is synchronized to
the Note On setting and the Arp/Motion Seq Grid setting of the specified Part.
Settings:
Part 1–Part 16
Arp/MS Grid (Arpeggio/Motion Sequencer Grid)
Determines the type of note that serves as the basis for the Quantize or Swing. The parameter value is
displayed in clocks. For Motion Sequencer, this parameter value is one step length. This setting is applied
to the Part which is selected as the Sync Part (above).
Settings:
60 (32nd note), 80 (16th note triplet), 120 (16th note), 160 (8th note triplet), 240 (8th note), 320 (1/4 note triplet),
480 (1/4 note)
Same as the Element Common Edit parameters for Normal Parts (AWM2) (
).
Lane