21
CRX-330/NS-BP100
CRX-330/NS-BP1
0
0
N o p r o t e c t i o n
While pressing these keys, turn on the power.
●
Starting Self-Diagnostic Function in the protection cancel mode
If the protection function works and causes hindrance to trouble shoot, cancel the protection function as described below,
and it will be possible to enter the self-diagnostic function mode.
While pressing those 2 keys of this unit as shown in the figure above, press the “STANDBY/ON” key to turn on the power
and keep pressing those 2 keys for 3 seconds or longer.
The self-diagnostic function mode is activated with the protection functions disabled.
In this mode, the “SLEEP” segment of the FL display of this unit flashes to indicate that the mode is self-diagnostic function
mode with the protection functions disabled.
CAUTION!
Using this product with the protection function disabled may cause damage to itself. Use special care when using this
mode.
●
Starting Self-Diagnostic Function
While pressing those 2 keys of this unit as shown in the figure below, press the “STANDBY/ON” key to turn on the power.
The self-diagnostic function mode is activated.
Keys of this unit
Display
●
Canceling Self-Diagnostic Function
1. Before canceling self-diagnostic function, execute setting of main menu B. FACTORY PRESET (Memory initialization
inhibited or Memory initialized).
*
In order to keep the user memory stored, be sure to select PRESET INH (Memory initialization inhibited).
2. Press the “STANDBY/ON” key of this unit to turn off the power.
Summary of Contents for MCR-330
Page 7: ...7 CRX 330 NS BP100 CRX 330 NS BP100 FRONT PANELS CRX 330 NS BP100 Top view Front view...
Page 8: ...8 CRX 330 NS BP100 CRX 330 NS BP100 REAR PANELS CRX 330 NS BP100...
Page 9: ...9 CRX 330 NS BP100 CRX 330 NS BP100 REMOTE CONTROL PANEL...
Page 69: ...69 CRX 330 NS BP100 CRX 330 NS BP100 MEMO...
Page 70: ...CRX 330 NS BP100...