background image

Updating the M7CL firmware 

IMPORTANT: If you intend on downgrading the M7CL-32/48 firmware V3 to V1 or V2, make 

sure to back up the internal data, then initialize the internal memory before updating. If you 

perform the update without initializing, operation of the M7CL may halt while a "Starting 

System" message is flashing on the lower-right of the screen, due to the difference in 

memory structures. In this case, turn off the power, then turn on the power again while 

holding down the SCENE MEMORY [STORE] key and [

] key. The internal memory will be 

forcibly initialized and the M7CL will start up in normal mode in around one minute. 

Updating the firmware V1 or V2 to V3, or V3.0x to V3.5x 

1.

 

Turn off the power to the M7CL. 

2.

 

Connect the USB storage device to the M7CL USB connector, then turn on the power to the M7CL.

 

A “Start Loading ?” message will be displayed.

 

3.

 

Click the OK button to start loading the firmware.

 

CAUTION: A “Loading...” message will appear during loading the firmware. The indication “......” will be 

displayed during the loading progress. Do not disconnect the USB storage device or power-off the M7CL 

while accessing the USB storage device.

 

4.

 

When the firmware has been loaded, the M7CL automatically restarts and a "Starting System..." 
message flashes. 

While this message is flashing, do not turn off the power because the internal memory will be 

initialized in around one minute. If you have accidentally turned off the power, turn on the power 

again to resume the initialization. 

5.

 

When a "Since M7CL was upgraded, Initialize all memories" popup window appears, press the 
CLOSE button to close it. 

6.

 

Press the EXIT button on the lower right of the startup menu screen to start up in normal mode. 

7.

 

Remove the USB storage device after confirming the ACCESS indicator has disappeared in the 
function access area. 

8.

 

If necessary, confirm the firmware was correctly updated in the version field in the SETUP screen. 
Also, if necessary, adjust the detection point of the touch screen (Calibration function) on the startup 

menu screen. For details, refer to the M7CL Owner's Manual. 

This completes the update procedure of the M7CL firmware. 

If you have backed up the necessary data, load it using the M7CL SAVE/LOAD function or the M7CL Editor 

(compatible with the updated firmware version). If a password has been set for Administrator, set the 

 

M7CL Upgrade Guide

 

 

3

 

Summary of Contents for M7CL StageMix V1.5

Page 1: ...he M7CL or remove the USB storage device while the update is in progress the M7CL may be damaged If the M7CL does not work properly after updating and you ve tried updating several times please contac...

Page 2: ...f your computer For details on the formatting procedure refer to the manual that came with your computer or USB storage device If you are formatting the media on the M7CL refer to the M7CL owner s man...

Page 3: ...device or power off the M7CL while accessing the USB storage device 4 When the firmware has been loaded the M7CL automatically restarts and a Starting System message flashes While this message is flas...

Page 4: ...ile accessing the USB storage device 4 When the firmware has been loaded power off the M7CL remove the USB storage device then turn on the power to the M7CL while holding down the SCENE MEMORY STORE k...

Page 5: ...e User Account Control dialog box may appear Click Continue or Yes You may be prompted to restart the computer after the installation is complete Before proceeding to step 3 restart the computer 3 Con...

Page 6: ...ponent for Firmware to program in the Program section Select firmware version 0x0C18 or later 10 Click the PROGRAM button in the Program section The update operation will begin The update will take ab...

Page 7: ...e EtherSound Devices section matches the firmware version to which you just updated If the version numbers do not match the update operation may have failed Try the update operation again starting fro...

Reviews: