04
PAMODE
CONTROL CHANGE
C O N T R O L
C H A N G E
07
08
09
0A
0B
0C
MIDI CHANNEL
The readouts will display the MIDI channel numbers
for banks A and B.
If you press the controller while pressing bank switch
A or B, the selected bank readout will start blinking.
Now you may enter the new channel number for that
bank. When you release the switch, the readout will
return to its usual display.
LOAD
Press and hold down the controller. Use the bank B
program select switches to select the code memory
you want to load. (recall)
A OCTAVE UP
B OCTAVE UP
A OCTAVE DOWN
B OCTAVE DOWN
Transposes bank A or B up or down one octave.
CHANNEL INCREMENT 1
0D CHANNEL DECREMENT 1
PARAMETER CHANGE
0E CHANNEL INCREMENT 2
0F CHANNEL DECREMENT 2
Moves the MIDI channel up or down 1 or 2. As with
other controller code assignments, this can be specified
for either/or A and B. The new MIDI channel number
will be displayed for about 0.5 seconds. If the number
goes beyond 16 or 1, it will come around to 1 or 16.
P A R A M E T E R
C H A N G E
16 DATA ENTRY
This corresponds to the data entry slider on the DX
series synthesizers.
26 INCREMENT
27 DECREMENT
These correspond to the +1 -1 switches on the DX
series synthesizers.
30 SONG SELECT
The upper readout will display SS. Now, select song
0-9 by pressing bank B program select switches 1-10.
31 MIDI CLOCK
When this controller code has been assigned to Wheel
1-Foot Controller 2, the KX88 will send MIDI tempo
clock data at a tempo of
= 40-240, according to the
position of the controller.
Note about controller codes.
The KX88 will send any type of MIDI data. However, some
MIDI devices may not accept certain messages.
Consult the MIDI data list for that device.
Use this to define controller codes 40-FF as MIDI control
change messages.
When you press this switch, the upper readout will show
CC . Enter the controller code number you want to define,
and the readout will show 00. Now enter the MIDI control
number (00-7F). Next, enter the data type. The data type
is significant only if this controller code is assigned to
Foot Switch 1 or 2. Regardless of the data type, TS1, 2
and MS1-5 will not send anything when turned off.
Data Type
Switch On
Switch off
0
Transmits 7F
Transmits 00
1
Transmits 7F
Nothing
2
Transmits 00
Nothing
Use this to define controller codes 40-FF as SYSTEM
EXCLUSIVE: PARAMETER CHANGE messages. When
you press this switch, the upper readout will show PC.
Enter the controller code you want to define. The upper
readout will shown LM (Limit) and the lower readout
will shown OF (Off). This allows you to select an upper
limit for the data of the parameter change. Use the bank
B program select switches 1-6 to select an upper limit of
3, 7, 15, 31, 63 or 99. If you press bank B switches 7-16,
the limit will be off. (127 max)
After you have specified the limit, the upper readout will
show G. Enter the group number (00-1F) of the parameter
you want to change. Next, the upper readout will show SG,
so enter the subgroup (0-3). Next, the upper readout will
show P, so enter the parameter number (00-FF).
NOTE:
System Exclusive messages include an ID number
which is different for each manufacturer. Con-
troller codes you define using PARAMETER
CHANGE will affect only Yamaha equipment. To
define System Exclusive messages for other
manufacturer’s products, use the Universal Para-
meter function.
- 1 1 -
Summary of Contents for KX88
Page 1: ...YAMAHA AUTHORIZED PRODUCT MANUAL MIDI MASTER KEYBOARD ...
Page 2: ...YAMAHA MIDI MASTER KEYBOARD OWNER S MANUAL ...
Page 23: ...KX88 BLOCKDIAGRAM 21 ...
Page 27: ...BINARY DECIMAL AND HEXADECIMAL CONVERSION Conversion Table 25 ...
Page 34: ...KX88 CONTROLLER ASSIGN TABLE SET NAME USER NAME CREATE DATE 3 2 ...
Page 37: ...SINCE 1887 YAMAHA NIPPON GAKKI CO LTD HAMAMATSU JAPANt ...