8
KMA-1000/KMA-950
KMA-1000/KMA-950
INDICATION OF PROTECTION INFORMATION
■
If any of indicators shown below fl ashes after turning on the power to this unit, it means that the protection func-
tion is at work and normal operation is not available.
●
Details of Protection Information
a. DC protection
Cause: Abnormal DC voltage of amplifi er output L/R
Normal value: 0.312 to 2.327 V
Detection port: PRD (58 pin of microprocessor IC15)
Detected at: Amplifi er output L/Rch of MAIN P.C.B.
b. I protection
Cause: Excess current fl ow into amplifi er
Normal value: Low (0 V)
Detection port: PRI (56 pin of microprocessor IC15)
Detected at: Amplifi er output L/Rch of MAIN P.C.B.
c. TH protection
Cause: Abnormal temperature of heat sink.
Normal value: 0.3 to 1.4 V
Detection port: TH_R (57 pin of microprocessor IC15)
Detected at: Heat sink temperature detection IC401 of MAIN P.C.B.
MUSIC indicator flashing: DC protection
MIC indicator flashing: TH protection
ECHO indicator flashing: I protection
KEY CONTROL indicator flashing in red/green alternately