7
EQ response curve
This indicates the frequency response of the current EQ settings. This is an approximate curve for your reference.
The markers (
) indicate the parameter values for each band. The color of the markers corresponds to the band number (1–6)
shown below.
By dragging a marker (left-click and move the mouse while holding down the button) you can specify the EQ response quickly
and visually. Use the parameter indications below to make fine adjustments to the values.
8
Type
The following EQ types can be specified for each band.
The default setting is [P.EQ] with the following parameter values.
9
Parameter indication (F/G/Q)
These indicate the center/cutoff frequency (F), gain (G), and Q. To edit the values, click the [
]/[
] buttons or use the mouse
to drag the markers (
) in the EQ response curve display.
Type
Parameter
Range
P.EQ (Peaking EQ)
F
40Hz – 18kHz
G
-15dB – +15dB
Q
0.5 – 12.0
HPF (High Pass Filter)
F
40Hz – 18kHz
Slope
12dB/oct (Fixed)
Q
0.7 (Fixed)
LPF (Low Pass Filter)
F
40Hz – 18kHz
Slope
12dB/oct (Fixed)
Q
0.7 (Fixed)
L.Shelf (Low Shelving EQ)
F
40Hz – 18kHz
G
-15dB – +15dB
H.Shelf (High Shelving EQ)
F
40Hz – 18kHz
G
-15dB – +15dB
Parameter
Default
Q
0.7 (common to all bands)
G
0.0dB(common to all bands)
F1
40Hz
F2
100Hz
F3
500Hz
F4
2kHz
F5
5kHz
F6
10kHz