44
YSP-600/HTY-760
YSP-600/HTY-760
K0/K1
(Panel key of this unit)
A/D of the key fails to function properly when the standard
value is deviated by
±
2%. In this case, check the constant
of voltage dividing resistor, solder condition, etc.
(Reference voltage: 3.3V=100%)
K0/K1
(本機パネルキー)
キーのA/Dは基準値から±2%を外れると、正常な動きをし
ません。下表をご覧になり、各キーの分圧抵抗の定数、ハ
ンダ不良等の確認をしてください。
(基準電圧:3.3V=100%)
[%]
0+2
10
±
2
100-2
K0
INPUT
NO KEY
K1
VOLUME -
–
NO KEY
K0:100
K1:099
9. AD DATA CHECK
This menu is used to display the A/D conversion value
of the main microprocessor which detects panel keys
of this unit and protection functions in % using the sub-
menu. During signal processing, the condition before
execution is maintained.
PS
(Power supply voltage protection detection)
* When the value of PS, P2 and P3 is not at the normal
value level, the protection function works and the power
is turned off.
(Reference voltage: 3.3V=100%)
PS (PS1)
Voltage detects:
-24V, +5V, +6.3V
Normal value:
48.7 to 91.3 %
(1.6 to 3.0 V)
P2 (PS2)
Voltage detects:
+12V, +10V, D+12
Normal value:
63.9 to 88.2 %
(2.1 to 2.9 V)
P3 (PS3)
Voltage detects:
+3.3 V
Normal value:
66.9 to 85.2 %
(2.2 to 2.8 V)
* The normal value has been revised from 2.5V
(measured value) to 3.3V (indicated value) by the
voltage dividing resistor.
9. AD DATA CHECK
本機のパネルキー、プロテクションなどを検出している
メインマイコンのA/D変換の値を、サブメニューで%表示
します。信号処理は実行前の状態を維持します。
PS
(電源電圧プロテクションの検出)
※ PS、P2、P3は正常値を外れるとプロテクションが働
き、電源オフされます。
(基準電圧:3.3V=100%)
PS(PS1)
検出電圧:
-24V、+5V、+6.3V
正常値:
48.7〜91.3 %(1.6〜3.0 V)
P2(PS2)
検出電圧:
+12 V、+10 V、D+12
正常値:
63.9〜88.2 %(2.1〜2.9 V)
P3(PS3)
検出電圧:
+3.3 V
正常値:
66.9〜85.2 %(2.2〜2.8 V)
※ 正常値は分圧抵抗によって2.5 V(実測値)から3.3 V
(表示値)へ変更されています。
PS:068%[2.24V]
P2:077%[2.54V]
P3:077%[2.54V]