12. FACTORY PRESET
This menu is used to reserve and inhibit initialization of the back-up RAM. The signals are processed using EFFECT OFF.
(The L/R signal is output using ANALOG MAIN BYPASS.)
11. RS-232C
This menu is unused.
PRESET INHIBIT
(Initialization inhibited)
RAM initialization is not executed. Select this sub-menu to protect the values set
by the user.
PRESET RESERVED
(Initialization reserved)
Initialization of the back-up RAM is reserved. (Actually, initialization is executed
the next time that the power is turned on.) Select this sub-menu to reset to the
original factory settings or to reset the RAM.
CAUTION:
Before setting to the PRESET RESERVED, write down the existing preset memory content of the Tuner in a
table as shown below. (This is because setting to the PRESET RESERVED will cause the user memory content
to be erased.)
Preset group
P1
P2
P3
P4
P5
P6
P7
P8
A
B
C
D
E
•
PRESET STATIONS
STATION
FM FACTORY PRESET DATA (MHz)
PAGE
NO.
U, C
R, T, K, A, B, G
1
87.5
87.5
2
90.1
90.1
3
95.1
95.1
A/C/E
4
98.1
98.1
5
107.9
108.0
6
88.1
88.1
7
106.1
106.1
8
107.9
108.0
STATION
AM FACTORY PRESET DATA (kHz)
PAGE
NO.
U, C, R, T, K
A, B, G
1
630
630
2
1080
1080
3
1440
1440
B/D
4
530
531
5
1710
1611
6
900
900
7
1350
1350
8
1400
1404
13. AD DATA CHECK/FAN TEST
This menu is used to display the A/D conversion value of the main CPU which detects panel keys of the main unit and
protection functions in % using the sub-menu. (Reference voltage 5V as 100%) During signal processing, the condition
before execution is maintained.
When K0/K1 menu is selected, keys become non-operable due to detection of the values of all keys. However, it is
possible to advance to the next sub-menu by turning the VOLUME of the main unit. When using this function, note that
turning the VOLUME more than 1 click would cause the volume value to change.
* The figures in the diagram are given as reference only.
DC/PS
(protection detection)
DC: DC detect protection value (Normal value: 1 to 13)
PS: Power supply voltage protection value (Normal value: 21 to 31)
* If DC or PS is out of the normal value range, the protection function works to turn off the
power.