5-27
ELEC
Electrical system
Checking the Rectifier Regulator
If the battery cables are connected in
reverse, the Rectifier Regulator can be
damaged.
1.
Disconnect the Rectifier Regulator cou-
pler
a
, and then connect the test har-
ness (3 pins)
a
.
2.
Measure the Rectifier Regulator output
peak voltage.
TIP:
Do not use peak voltage adapter B when
measuring the Rectifier Regulator output
peak voltage.
3.
Disconnect the test harness
a
and light-
ing coil coupler.
4.
Make sure to set the measurement range
b
, and display the mark
c
by pushing
the switch
d
.
A
Tester model CD721
B
Tester model CD731a
5.
Check the Rectifier Regulator for continu-
ity. Replace if out of specification.
Test harness (3 pins)
a
: 90890-06846
Rectifier Regulator output peak voltage:
Red (R)–Ground
r/min
Loaded
1500
3500
DC V
13.0
13.0
R
R
R R
B
B
a
a
a
b
c
d
A
b
c
d
B
e
f
g
h
k
m
e
f
g
h
k
m