(F01) MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI
F11/F01 Data List
25
• Caution: If an error occurs during MIDI reception, the Damper, Sos-
tenuto, and Soft effects for all channels are turned off and an All
Note Off occurs.
6. SYSTEM EXCLUSIVE MESSAGES (Yamaha MIDI For-
mat)
Panel Data Transmit
Data format: [F0H]
➝
[43H]
➝
[0nH]
➝
[7CH]
➝
...
➝
[F7H]
F0H, 43H, 0nH, 7CH (n: channel number)
00H, LLH (data length)
43H, 4CH, 20H, 20H (CL)
43H, 4CH, 50H, 27H, 30H, 35H
3xH, 3yH
aaH, bbH: Device No. aa=LSB, bb=MSB
aa=72H, bb=17H
[PANEL DATA]
[CHECK SUM (1byte)] = 0-(43H+4CH+20H+......+Data end)
F7H
• Panel Data Contents
• Panel data send requests cannot be received.
7. SYSTEM EXCLUSIVE MESSAGES
(Universal System Exclusive)
(1) Universal Realtime Message
Data format: [F0H]
➝
[7FH]
➝
[XnH]
➝
[04H]
➝
[01H]
➝
[llH]
➝
[mmH]
➝
[F7H]
MIDI Master Volume
• Simultaneously changes the volume of all channels.
• When a MIDI master volume message is received, the volume only
has affect on the MIDI receive channel, not the panel master vol-
ume.
F0H = Exclusive status
7FH = Universal Realtime
7FH = ID of target device
04H = Sub-ID #1=Device Control Message
01H = Sub-ID #2=Master Volume
ll
H =
Volume LSB
mmH =
Volume MSB
F7H = End of Exclusive
or
F0H = Exclusive status
7FH = Universal Realtime
XnH = When n is received n=0-F, whichever is received.
X = don’t care
04H = Sub-ID #1=Device Control Message
01H = Sub-ID #2=Master Volume
ll
H =
Volume LSB
mmH =
Volume MSB
F7H = End of Exclusive
(2) Universal Non-Realtime Message (GM On)
General MIDI Mode On
Data format: [F0H]
➝
[7EH]
➝
[XnH]
➝
[09H]
➝
[01H]
➝
[F7H]
F0H = Exclusive status
7EH = Universal Non-Realtime
7FH = ID of target device
09H = Sub-ID #1=General MIDI Message
01H = Sub-ID #2=General MIDI On
F7H = End of Exclusive
or
F0H = Exclusive status
7EH = Universal Non-Realtime
XnH = When received, n=0-F.
X = don’t care
09H = Sub-ID #1=General MIDI Message
01H = Sub-ID #2=General MIDI On
F7H = End of Exclusive
When the General MIDI mode ON message is received, the MIDI
system will be reset to its default settings.
This message requires approximately 50ms to execute, so suffi-
cient time should be allowed before the next message is sent.
8. SYSTEM EXCLUSIVE MESSAGES (XG Standard)
(1) XG Native Parameter Change
Data format: [F0H]
➝
[43H]
➝
[1nH]
➝
[4CH]
➝
[hhH]
➝
[mmH]
➝
[
ll
H]
➝
[ddH]
➝
[F7H]
F0H = Exclusive status
43H = YAMAHA ID
1nH = When received, n=0-F.
When transmitted, n=0.
4CH = Model ID of XG
hhH = Address High
mmH =
Address Mid
ll
H =
Address Low
ddH = Data
|
F7H = End of Exclusive
Data size must match parameter size (2 or 4 bytes).
When the XG System On message is received, the MIDI system
will be reset to its default settings.
The message requires approximately 50ms to execute, so suffi-
cient time should be allowed before the next message is sent.
(2) XG Native Bulk Data (reception only)
Data format: [F0H]
➝
[43H]
➝
[0nH]
➝
[4CH]
➝
[aaH]
➝
[bbH]
➝
[hhH]
➝
[mmH]
➝
[
ll
H]
➝
[ddH]
➝
...
➝
[ccH]
➝
[F7H]
F0H = Exclusive status
43H = YAMAHA ID
0nH = When received, n=0-F.
When transmitted, n=0.
4CH = Model ID of XG
aaH = ByteCount
bbH = ByteCount
hhH = Address High
mmH =
Address Mid
ll
H =
Address Low
ddH = Data
| |
| |
ccH = Check sum
F7H = End of Exclusive
• Receipt of the XG SYSTEM ON message causes reinitialization of
relevant parameters and Control Change values. Allow sufficient
time for processing to execute (about 50 msec) before sending the
CLP-240/230 another message.
• XG Native Parameter Change message may contain two or four
bytes of parameter data (depending on the parameter size).
• For information about the Address and Byte Count values, refer to
Table 1 below. Note that the table’s Total Size value gives the size
of a bulk block. Only the top address of the block (00H, 00H, 00H)
is valid as a bulk data address.
Data
Transmission
Reception
F8H
Transmitted every
96 clocks
Received as 96-clock tempo timing when
MIDI clock is set to External
FAH
Recorder start
Recorder start
Not received when the MIDI clock is set to
Internal.
FCH
Recorder stop
Recorder stop
Not received when the MIDI clock is set to
Internal.
FEH
Transmitted every
200 milliseconds
If a signal is not received via MIDI for more
than 400 milliseconds, the same processing
will take place for All Sound Off, All Notes Off
and Reset All Controllers as when those sig-
nals are received.
(1) 1'st Voice
(2) Dual On/Off
(3) Dual Voice
(4) Dual Balance
(5) Dual Detune
(6) Dual Voice1 Octave
(7) Dual Voice2 Octave
(8) Dual Voice1 Effect Depth
(9) Dual Voice2 Effect Depth
(10) Split On/Off
(11) Split Voice
(12) Split Point
(13) Split Balance
(14) Split Voice1 Octave
(15) Split Voice2 Octave
(16) Split Voice1 Effect Depth
(17) Split Voice2 Effect Depth
(18) Split Dumper Mode
(19) Reverb Type 1
(20) Reverb Type 2
(21) Reverb Depth 1
(22) Reverb Depth 2
(23) Effect Type 1
(24) Effect Type 2
(25) Effect Depth
(26) Variation On/Off
(27) Touch Sensitivity
(28) Fixed Data
(29) Soft Pedal Depth
(30) Absolute tempo low byte
(31) Absolute tempo high byte
(32) Key-Off Sampling Depth
(33) DDE On/Off
(34) DDE Depth
(35) Brilliance