
43
1. NOTE ON/OFF
STATUS: 9nH/8nH
2. PROGRAM CHANGE
STATUS: CnH
3. PITCH BEND CHANGE
STATUS: EnH
4. CONTROL CHANGE
STATUS: BnH
<BANK SELECT MSB/LSB> 00H/20H
Cntrl#
parameter
Data Range
0
Bank Select MSB
63 (0x3F):Exclusive to EX
32
Bank Select LSB
0 (0x00):Preset1 Voice
1 (0x01):Preset2 Voice
2 (0x02):Internal1 Voice
3 (0x03):Internal2 Voice
64 (0x40):Performance
0
Bank Select MSB
0 (0x00): GM
32
Bank Select LSB
0 (0x00):Internal1 Voice
0
Bank Select MSB
127(0x7F): GM
32
Bank Select LSB
0 (0x00):Internal2 Voice
New bank selection will not become effective until the Program Change message is received.
<MODULATION> 01H
Cntrl#
parameter
Data Range
1
Modulation
0...127
<BREATH CONTROLLER> 02H
Cntrl#
parameter
Data Range
2
Breath Controller
0...127
<FOOT CONTROLLER> 04H
Cntrl#
parameter
Data Range
4
Foot Controller
0...127
<PORTAMENTO TIME> 05H
Cntrl#
parameter
Data Range
5
Portamento Time
0...127
Setting the value to 127 produces maximum portamento time and 0 results in minimum portamento
time.
<DATA ENTRY MSB/LSB> 06H/26H
Cntrl#
parameter
Data Range
6
Data Entry MSB
0...127
38
Data Entry LSB
0...127
Messages which set the value for the parameter specified by RPN.
<MAIN VOLUME> 07H
Cntrl#
parameter
Data Range
7
Main Volume
0...127
<PAN POT> 0AH
Cntrl#
parameter
Data Range
10
Panpot
0...127
Setting the value to 127 positions to the right most and 0 positions to the left most.
<EXPRESSION> 0BH
Cntrl#
parameter
Data Range
11
Expression
0...127
<CONTROL CHANGE 13> 0DH
Cntrl#
parameter
Data Range
13
Control Change 13
0...127
<SUSTAIN> 40H
Cntrl#
parameter
Data Range
64
Sustain
0...127 (0-63:Off, 64-127:On)
<PORTAMENTO> 41H
Cntrl#
parameter
Data Range
65
Portamento
0...127 (0-63:Off, 64-127:On)
Portamento is applied according to the amount set in the Portamento Time when the Prtament is
set to ON. MONO is selected when the Prtament is set to ON: Single Trigger mode is selected. In
the other cases: Multi Trigger mode.
<SOSTENUTO> 42H
Cntrl#
parameter
Data Range
66
Sostenuto
0...127 (0-63:Off, 64-127:On)
<HARMONIC CONTENT> 47H
Cntrl#
parameter
Data Range
71
Harmonic Content
0...127 (0:-64, 64:+0, 127:+63)
Adjusts the resonance. Effective range may be narrower than the available range.
<RELEASE TIME> 48H
Cntrl#
parameter
Data Range
72
Release Time
0...127 (0:-64, 64:+0, 127:+63)
Adjusts the envelope release time. Effective range may be narrower than the available range.
<ATTACK TIME> 49H
Cntrl#
parameter
Data Range
73
Attack Time
0...127 (0:-64, 64:+0, 127:+63)
Adjusts the envelope attack time. Effective range may be narrower than the available range.
<BRIGHTNESS> 4AH
Cntrl#
parameter
Data Range
74
Brightness
0...127 (0:-64, 64:+0, 127:+63)
Default:40H
Adjusts the filter cut-off frequency. Effective range may be narrower than the available range.
<PORTAMENT CONTROL> 54H
Cntrl#
parameter
Data Range
84
Portamento control
0...127
<EFFECT SEND LEVEL 1 (REVERB)> 5BH
Cntrl#
parameter
Data Range
91
Effect 1 Depth
0...127
Adjusts the reverb send level.
<EFFECT SEND LEVEL 3 (CHORUS)> 5DH
Cntrl#
parameter
Data Range
93
Effect3 Depth
0...127
Adjusts the chorus send level.
<DATA INCREMENT/DECREMENT> 60H/61H
Cntrl#
parameter
Data Range
96
Increment
0...127
97
Decrement
0...127
The data byte is ignored.
Messages which increase or decrease the MSB value designated by RPN.
<REGISTERED PARAMETER NUMBER (RPN) LSB/MSB> 64H/65H
Cntrl#
parameter
Data Range
100
RPN LSB
0...127
101
RPN MSB
0...127
The following parameters can be designated.
RPN
LSB
MSB
MSB
parameter
Data Range
00H
00H
mmH
Pitch Bend Sensitivity
mm:00H-18H(0-+24)
Default:02H
01H
00H
mmH
Fine Tune
mm:00H-40H-7FH(-64-0-+63)
Default : 40H 00H
02H
00H
mmH
Coarse Tune
mm:28H-40H-58H(-24-0-+24)
Default : 40H 00H
7FH
7FH
---
Null
---
5. CHANNEL MODE MESSAGES
<ALL SOUNDS OFF > 78H
Cntrl#
parameter
Data Range
120
-----
0
All the sounds currently played except for the channel messages are muted when receiving this
message.
<RESET ALL CONTROLLERS> 79H
Cntrl#
parameter
Data Range
121
-----
0
Resets the values set for the following controllers.
PITCH BEND CHANGE
Center
CHANNEL AFTER TOUCH
0
MODULATION
0
BREATH CONTROLLER
Maximum
FOOT CONTROLLER
Maximum
EXPRESSION
Maximum
CONTROL CHANGE 13
Center
SUSTAIN SWITCH
Off
PORTAMENTO SWITCH
Off
SOSTENUTO SWITCH
Off
RPN
Null
Resets the Portamento Control setting.
<ALL NOTES OFF> 7BH
Cntrl#
parameter
Data Range
123
---------
0
All the notes currently set to on in a certain channel are muted when receiving this message.
However, if Hold 1 or Sostenute is on, notes will continue sounding until these are turned off.
<OMNI MODE OFF> 7CH
Cntrl#
parameter
Data Range
124
---------
0
Performs the same function as when receiving ALL NOTES OFF.
<OMNI MODE ON> 7DH
Cntrl#
parameter
Data Range
125
-----
0
Performs the same function as when receiving ALL NOTES OFF.
Summary of Contents for EX7
Page 54: ...54 MEMO ...