1-4
Yamaha Generator Theory & Diagnostics Guide
AC OUTPUTS
There are two levels of output available from Yamaha
generators:
1.
Peak Output
(short period of time).
2.
Rated Output
(continuous duty).
In normal operation of course, these levels would
merge. The built-in Thermal or Nonfuse Breakers
(NFB) are designed to protect against harmful over-
loads, while allowing for these different levels. The
length of time the breaker allows the generator to
produce a particular level without interrupting the
current flow varies. This flexibility permits the gen-
erator to be used for a wide variety of applications:
1. The stated
peak output
is the amount of cur-
rent that can be utilized for short time periods
before the NFB disconnects the output. This
output level allows for jobs of short duration,
requiring maximum output (tool startup).
2. The
rated output
is the amount of current the
generator can supply for continuous operation.
12 Volt DC Output
The DC output is intended only to charge a 12-volt
battery. If any 12-volt devices should be connected
to a 12V battery and never to the 12V plug on the
generator. It is possible that a device could be dam-
aged if it is connected directly to a generator.
The DC output is controlled only by the capability,
condition, and state of charge of the battery.
Voltage and Frequency Standards
In the U.S., standard commercial electricity is deliv-
ered at 110~120 V AC, and 220~240 V AC. The
electrical frequency standard is 60 cycles per sec-
ond (60 Hz).
Multi-pole Alternator Features
Used in Inverter Generators
The combination of ferrite magnets in the rotor and
multi-pole stator provides a compact and high per-
formance alternator.
High-frequency multi-pole alternator features:
16-pole rotor
24-pole stator coil
3-phase AC power generation
Exhaust pipe
Engine
Alternator
Muffler
Fuel tank
Control unit
Recoil starter
Battery
EF3000iSE/EF3000iSEB
Control unit
*
EF3000iSE new model guide 3/14/03 4:20 PM Page 2
EF3000iSE/EF3000iSEB
CONTROL UNIT
Reference information:
Ferrite magnets are magnetically stable and have a
strong coercive force and so do not become demag-
netized. While they have excellent corrosion resis-
tance, they are also brittle due to the way they are
produced.
Great care must be taken when assem-
bling them as jarring or shocks of force can
adversely affect their efficiency and/or cause
breakage .
Control Unit
The control unit is a sealed unit.
Functions:
AC power generation
Electronic governor (throttle control)
Economy control program
Self-protective function
Over current
Over voltage
High temperature
Summary of Contents for EF4500iSE - Inverter Generator
Page 1: ...YAMAHA GENERATOR THEORY DIAGNOSTICS GUIDE...
Page 4: ......
Page 34: ......
Page 50: ...2 16 Yamaha Generator Theory Diagnostics Guide...
Page 51: ...2 17 Generator Diagnostics...
Page 53: ...2 19 Inverter Generator Diagnostics...
Page 54: ...2 20 Yamaha Generator Theory Diagnostics Guide...
Page 76: ......
Page 101: ...3 25 Current Model Specifications and Wiring Diagrams EF2800i INVERTER GENERATOR EF2800i...
Page 102: ...3 26 Yamaha Generator Theory Diagnostics Guide EF2800i WIRING DIAGRAM...
Page 103: ...3 27 Current Model Specifications and Wiring Diagrams EF2800i 5W 30...
Page 104: ...3 28 Yamaha Generator Theory Diagnostics Guide...
Page 105: ...3 29 Current Model Specifications and Wiring Diagrams EF2800i...
Page 106: ...3 30 Yamaha Generator Theory Diagnostics Guide...
Page 107: ...3 31 Current Model Specifications and Wiring Diagrams EF2800i...
Page 108: ...3 32 Yamaha Generator Theory Diagnostics Guide...
Page 117: ...3 41 Current Model Specifications and Wiring Diagrams YG4000DE...
Page 118: ...3 42 Yamaha Generator Theory Diagnostics Guide INVERTER GENERATOR EF4000DE...
Page 119: ...3 43 Current Model Specifications and Wiring Diagrams YG4000DE 5W 30...
Page 120: ...3 44 Yamaha Generator Theory Diagnostics Guide...
Page 121: ...3 45 Current Model Specifications and Wiring Diagrams YG4000DE...
Page 122: ...3 46 Yamaha Generator Theory Diagnostics Guide...
Page 123: ...3 47 Current Model Specifications and Wiring Diagrams YG4000DE...
Page 124: ...3 48 Yamaha Generator Theory Diagnostics Guide...
Page 125: ...3 49 Current Model Specifications and Wiring Diagrams YG4000DE...
Page 126: ...3 50 Yamaha Generator Theory Diagnostics Guide INVERTER GENERATOR EF4500iSE...
Page 127: ...3 51 Current Model Specifications and Wiring Diagrams EF4500iSE EF4500iSE WIRING DIAGRAM...
Page 128: ...3 52 Yamaha Generator Theory Diagnostics Guide...
Page 129: ...3 53 Current Model Specifications and Wiring Diagrams EF4500iSE 5W 30...
Page 130: ...3 54 Yamaha Generator Theory Diagnostics Guide...
Page 131: ...3 55 Current Model Specifications and Wiring Diagrams EF4500iSE...
Page 132: ...3 56 Yamaha Generator Theory Diagnostics Guide...
Page 133: ...3 57 Current Model Specifications and Wiring Diagrams EF4500iSE...
Page 134: ...3 58 Yamaha Generator Theory Diagnostics Guide...
Page 135: ...3 59 Current Model Specifications and Wiring Diagrams EF4500iSE...
Page 136: ...3 60 Yamaha Generator Theory Diagnostics Guide...
Page 147: ...3 71 Current Model Specifications and Wiring Diagrams EF6300iSDE INVERTER GENERATOR EF6300iSDE...
Page 148: ...3 72 Yamaha Generator Theory Diagnostics Guide EF6300iSDE WIRING DIAGRAM...
Page 149: ...3 73 Current Model Specifications and Wiring Diagrams EF6300iSDE...
Page 150: ...3 74 Yamaha Generator Theory Diagnostics Guide...
Page 151: ...3 75 Current Model Specifications and Wiring Diagrams EF6300iSDE...
Page 152: ...3 76 Yamaha Generator Theory Diagnostics Guide...
Page 164: ...3 88 Yamaha Generator Theory Diagnostics Guide EF12000DE...
Page 165: ...3 89 Current Model Specifications and Wiring Diagrams EF12000DE EF12000DE...
Page 166: ...3 90 Yamaha Generator Theory Diagnostics Guide EF12000DE...
Page 167: ...3 91 Current Model Specifications and Wiring Diagrams EF12000DE EF12000DE...
Page 168: ...3 92 Yamaha Generator Theory Diagnostics Guide EF12000DE...
Page 169: ...3 93 Current Model Specifications and Wiring Diagrams EF12000DE EF12000DE...
Page 170: ...3 94 Yamaha Generator Theory Diagnostics Guide CONVENTIONAL GENERATOR EF12000DE Control Box...
Page 171: ...3 95 Current Model Specifications and Wiring Diagrams EF1200DE EF12000DE WIRING DIAGRAM...
Page 180: ...3 104 Yamaha Generator Theory Diagnostics Guide CONVENTIONAL GENERATOR YG4000D...
Page 181: ...3 105 Current Model Specifications and Wiring Diagrams YG4000D...
Page 182: ...3 106 Yamaha Generator Theory Diagnostics Guide YG4000D WIRING DIAGRAM...
Page 183: ...3 107 Current Model Specifications and Wiring Diagrams YG4000D...
Page 184: ...3 108 Yamaha Generator Theory Diagnostics Guide 5W 30...
Page 185: ...3 109 Current Model Specifications and Wiring Diagrams YG4000D...
Page 186: ...3 110 Yamaha Generator Theory Diagnostics Guide...
Page 187: ...3 111 Current Model Specifications and Wiring Diagrams YG4000D...
Page 188: ...3 112 Yamaha Generator Theory Diagnostics Guide...
Page 189: ...3 113 Current Model Specifications and Wiring Diagrams YG4000D...
Page 190: ...3 114 Yamaha Generator Theory Diagnostics Guide...
Page 218: ...2009 Yamaha Motor Corporation U S A Printed in U S A LIT BKTEC GN 01...