RX-Z11/DSP-Z11
42
•
Starting Self-Diagnostic Function in the
protection cancel mode
If the protection function works and causes hindrance to
trouble shoot, cancel the protection function as described
below, and it will be possible to enter the self-diagnostic
function mode. (The protection functions other than the
excess current detect function will be disabled.)
Press the “MASTER ON/OFF” key while simultaneously
pressing the “PROGRAM” knob and “MENU” key of this
unit as indicated in the figure above. At this time, keep
pressing the “PROGRAM” knob and “MENU” key for 3
seconds or longer.
The self-diagnostic function is activated in the protection
cancel mode.
In this mode, the “SLEEP” segment of the FL display of
this unit flashes to indicate that the mode is self-diagnostic
function mode with the protection functions disabled.
● プロテクション解除モードでの起動
プロテクションが動作することにより、故障箇所の診断に
支障をきたすような場合は、次の方法によりプロテクショ
ンを解除した状態でダイアグモードに入ることができま
す。(過電流検出以外のプロテクション動作を解除する)
上図の PROGRAM ノブと MENU キーを同時に押しなが
ら M A S T E R O N / O F F キーを押します。このとき、
PROGRAM ノブと MENU キーを3秒以上押し続けま
す。
プロテクション解除モードでダイアグが起動します。
このモードでは本機FLの SLEEP セグメントが点滅し、
プロテクションを解除した状態でのダイアグモードである
ことを知らせます。
注意!
プロテクションを解除した状態でのダイアグモードは、
危険な状態でもプロテクションが作動しないため、動作
させると、機器を破壊することがあります。このモード
を使用する場合は十分注意してください。
● ダイアグの解除
① ダイアグを解除する前に、メインメニューNo. 27の
FACTORY PRESET
(メモリーの初期化禁止/またはメ
モリーの初期化)の設定をします。
※ ユ ー ザ ー メ モ リ ー を 保 持 し た い 場 合 は 、 必 ず
PRESET INHIBIT(メモリー初期化禁止)を選択し
てください。
② 本機の MASTER ON/OFF キーかリモコンの STANDBY
キーを押し、パワーオフにします。
•
Canceling Self-Diagnostic Function
1
Before canceling self-diagnostic function, execute
setting for PRESET of main menu No. 27 (Memory ini-
tialization inhibited or Memory initialized).
*
In order to keep the user memory stored, be sure
to select PRESET INHIBIT (Memory initialization
inhibited).
2
Turn off the power by pressing the “MASTER ON/
OFF” key of this unit or the “STANDBY” key of the re-
mote control.
CAUTION!
Using this product with the protection function disabled
may cause damage to itself. Use special care when us-
ing this mode.
•
Starting Self-Diagnostic Function
Press the “MASTER ON/OFF” key while simultaneously
pressing the “PROGRAM” knob and “MENU” key of this
unit as indicated in the figure below.
The self-diagnostic function is activated.
● ダイアグの起動
下図に示す本機の PROGRAM ノブと MENU キーを押し
ながら MASTER ON/OFF キーを押すと、ダイアグが起動
します。
"MENU" key
"MENU"キー
"PROGRAM" knob
"PROGRAM"ノブ
Turn on the power while pressing these knob and key.
これらのノブとキーを同時に押しながら、パワーオンする。
原因:
パワーアンプに過電流が流れた。
補足:
パワートランジスタの電流を検出していますので、
電流検出トランジスタをチェックすれば異常チャン
ネルが特定できます。
異常状態のままパワーオンすると、瞬時にプロテクション
がかかり、すぐに電源が切れます。
When there is a history of protection function:
When there is a history of protection function due
to excess current
プロテクション履歴がある場合:
過電流によるプロテクション履歴がある場合
•
Display provided when Self-Diagnos-
tic Function started
The FL display of this unit displays the protection function
history data and the version (1 alphabet) then the main
menu (sub-menu MARGIN of main menu No. 1 DSP
THROUGH) a few seconds later.
When there is no history of protection function:
● ダイアグ起動時の表示
本機のFLディスプレイにプロテクション履歴情報とバー
ジョン(英1文字)が表示され、数秒後にメインメニュー
(No. 1 DSP THROUGHのサブメニューMARGIN)
になりま
す。
プロテクション履歴がない場合:
Cause:
An excessive current flowed through the power
amplifier.
Supplementary information:
As current of the power
transistor is detected, the abnormal channel can be
identified by checking the current detect transistor.
Turning on the power without correcting the abnormality
will cause the protection function to work immediately and
the power supply will instantly be shut off.
After a few seconds /
数秒後
Main menu display /
メインメニュー表示
Opening message /
オープニング表示
When there is no protection history
プロテクション履歴が無い場合
When there is a history of protection
function due to excess current
過電流によるプロテクション履歴が
ある場合
注意!
・ 異常状態のまま本機の電源を入れると、危険な状態に
なり、さらに回路が損傷を受ける原因になります。そ
のため連続してプロテクションが働いた場合、3回目
以降 MASTER ON/OFF キーを押しても電源が入らな
くなります。再度電源を入れる場合、一度本機の電源
コードをAC電源コンセントから抜いて接続し直してく
ださい。
・ 本機の電源をいれる前に、各パワーアンプの出力トラ
ンジスタに損傷がないかチェックしてください。
・ パワーアンプの電流は、各チャンネルのエミッターの
抵抗器間DC電圧を測定することによりモニターして
ください。
Note)
• Applying the power to this unit without correcting
the abnormality can be dangerous and cause ad-
ditional circuit damage. To avoid this, if protection
function has been activated 3 times continuously,
the power will not turn on even when the “MAS-
TER ON/OFF” key is pressed. In order to turn on
the power again, disconnect the power cable of
this unit from the AC outlet once and then recon-
nect it again.
• The output transistors in each power amplifier
should be checked for damage before applying
power to this unit.
• Power amplifier current should be monitored by
measuring DC voltage across the emitter resistors
for each channel.
DIAGNOSTIC
NO
PROTECTION
H
1.DSP
THROUGH
MARGIN
DIAGNOSTIC
I
PROTECT
H
DIAG:RRT-INH
NO
PROTECTION
H
Knob and key of this unit /
本機のノブとキー
Summary of Contents for DSP-Z11
Page 5: ...RX Z11 DSP Z11 5 RX Z11 DSP Z11 DSP Z11 J model RX Z11 A model ...
Page 6: ...RX Z11 DSP Z11 6 RX Z11 DSP Z11 REAR PANELS RX Z11 U model RX Z11 C model ...
Page 7: ...RX Z11 DSP Z11 7 RX Z11 DSP Z11 RX Z11 R model RX Z11 T model ...
Page 8: ...RX Z11 DSP Z11 8 RX Z11 DSP Z11 RX Z11 K model RX Z11 A model ...
Page 9: ...RX Z11 DSP Z11 9 RX Z11 DSP Z11 DSP Z11 B model DSP Z11 G E models ...
Page 10: ...RX Z11 DSP Z11 10 RX Z11 DSP Z11 DSP Z11 L model DSP Z11 J model ...
Page 39: ...39 RX Z11 DSP Z11 RX Z11 DSP Z11 MEMO MEMO ...
Page 240: ...RX Z11 DSP Z11 241 ...
Page 241: ...RX Z11 DSP Z11 242 ...
Page 242: ...243 RX Z11 DSP Z11 RX Z11 DSP Z11 MEMO MEMO ...
Page 243: ...RX Z11 DSP Z11 ...