AMP ADJUSTMENT
/ アンプ部調整
0.1mV ~ 10.0mV
(DC)
0.1mV ~ 10.0mV
(DC)
R61 (MAIN Lch)
R62 (MAIN Rch)
R67 (CENTER)
R37 (MAIN Lch)
R38 (MAIN Rch)
R40 (CENTER)
R41 (REAR Lch)
R42 (REAR Rch)
R39 (REAR Cch)
R68 (REAR Lch)
R69 (REAR Rch)
R63 (REAR Cch)
Cut off
カット
Confirmation of Idling Current of Main (1)
and (2) P.C.B.
• Right after power is turned on, confirm that the voltage
across the terminals of R113 (Main Lch), R133 (Main
Rch), R187 (Center), R151 (Rear Lch), R169 (Rear
Rch), R972 (Rear Center) are between 0.1mV and
10.0mV.
• If it exceeds 10.0mV, open (cutoff) R106 (Main Lch),
R126 (Main Rch), R183 (Center), R146 (Rear Lch),
R164 (Rear Rch), R967 (Rear Cch) and reconfirm the
voltage.
• Confirm that the voltage is 0.2 mV ~ 15.0 mV after 60
minutes.
メイン
(1)
、
(2)
P.C.B.のアイドリング電流
の確認
● 電源投入直後、R61 (MAIN Lch)、R62 (MAIN Rch)、
R67 (CENTER)、R68 (REAR Lch)、R69 (REAR
Rch)、R63 (REAR Center)の端子間電圧を測定し、
0.1mVから10.0mVの間であることを確認してくださ
い。
● 電圧が10mVを超えている場合は、R37(MAIN Lch)、
R38 (MAIN Rch)、R40 (CENTER)、R41 (REAR
Lch)、R42 (REAR Rch)、R39 (REAR Cch)をカット
し、電圧を再確認してください。
● 60分後、電圧が0.2mV〜15.0mVであることを確認して
ください。