Page 2: ...into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the...
Page 3: ...4 522 9011 Type of Equipment DIGITAL MIXING ENGINE SATELLITE Model Name DME8i ES DME8o ES DME4io ES This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including inter ference that may cause undesired operation See user manual instructions if ...
Page 4: ...e the electric plug from the outlet when the device is not to be used for extended periods of time or during electrical storms When removing the electric plug from the device or an outlet always hold the plug itself and not the cord Pulling by the cord can damage it Before moving the device remove all connected cables When setting up the device make sure that the AC outlet you are using is easily ...
Page 5: ...rge becomes low the ERROR indicator on the front panel blinks In this case save the data to a computer immediately then ask a Yamaha dealer to replace the backup battery Do not turn the POWER switch on and off repeatedly and rapidly Be sure to wait six seconds or more between turning the power to the unit off and then on The rubber feet included in this package can be attached to the speaker to pr...
Page 6: ...O Connection 24 Digital Audio Connection EtherSound Connectors 24 Analog Audio Connection INPUT OUTPUT Connectors 25 Connecting to an External Device 26 Remote Connection REMOTE Connector 26 Controlling external head amplifiers from the DME Satellite 26 Controlling a DME Satellite s internal head amps from a digital mixer 27 Controlling the DME Satellite from an external device 27 EtherSound Conne...
Page 7: ... end of the AC cord into the AC IN socket on the rear panel of the DME Satellite then plug the male plug into an appropriate AC mains outlet Be sure to use the voltage specified for the device Turning the power on and off 1 Press the POWER switch to turn on the power to the DME Satellite 2 Press the POWER switch again to turn off the power Foreword NOTE For more information on your Control Panel r...
Page 8: ... on the device enable you to remotely control analog inputs and outputs by transfer ring digital audio signals via a network The following steps summarize the process for setting up the DME Satellite for use For details refer to the PDF file DME Setup Manual on the CD ROM 1 Install USB MIDI Driver DME Designer and DME N Network Driver 2 Set up the network from DME Designer page 19 3 Connect device...
Page 9: ...the computer to control an entire device group via the group master Glossary for the DME Satellite This section explains terminology specific to the DME Satellite Components and parameters The individual audio processing modules equalizers compressors etc are called components External head amplifier control modules are also available as components Changing the parameters of components enables con...
Page 10: ...nd preset parameters is called a scene Scenes can be recalled from an ICP1 GPI device other external controllers DME64N DME24N or computer Up to 999 scenes can be stored for each device group Scene structure Scene change 16 x 8 Scene Scene 1 Scene 2 Scene 999 Component Configuration Preset Parameter Ex Gate Attack Decay Range Threshold Key in Hold Matrix Mixer First Act Dark Change Second Act Band...
Page 11: ...ontrol signals between devices outside the device group These signals provide communication and control between individual devices Included in this category are MIDI messages transferred between USB connectors GPI signals transferred be tween GPI connectors and remote head amp control signals handled via the REMOTE connector Type of signals handled by the DME Satellite Connector Audio Signal Devic...
Page 12: ...d EtherSound device This connector can also be used in common with the same network as Ethernet Control Units following the OUT connector of the first EtherSound device cannot be used in common with the same network as Ethernet Control ICP1 Computer Hub Hub Hub Hub M7CL DME8i ES DME8i ES DME4io ES DME8o ES DME8o ES DME8o ES DME4io ES DME8o ES DME8i ES Space B Space A Space C Space D Analog In Anal...
Page 13: ...the USB or Ethernet connection DME series settings configuration and parameter data is sent via USB or Ethernet to the connected DME series unit After the data is transmitted you can disconnect the DME series unit from the computer and use it as an independent processor You can also connect it to a computer and control it in realtime from DME Designer If multiple DME series units are connected in ...
Page 14: ...ge while data communication is occurring via the USB or NETWORK connector 3 MASTER Indicator Lights green when the device is operating as the group mas ter The indicator is turned off if the device is operating as a slave You can assign the group master in DME Designer Controls and Connectors 2 6 345 1 7 8 9 2 6 345 1 7 8 9 2 6 345 1 7 8 9 DME8i ES DME8o ES DME4io ES Before you connect the DME Sat...
Page 15: ...therSound IN connector OUTPUT Indicates the communication status of the EtherSound OUT connector 6 PEAK Indicators Light red when the signal level at the corresponding built in analog audio inputs or outputs INPUT or OUTPUT connectors reaches or exceeds 3 dBFS They also indicate an error number or status 7 SIGNAL Indicators Light green when the signal level at the corresponding built in analog aud...
Page 16: ...ctor This is a 100Base TX 10Base T Ethernet connector for con nection to a computer or to another DME series unit in the network See Ethernet Connection NETWORK Con nector on page 20 for connection details 5 Dip Switch This 6 bit dip switch enables you to select the REMOTE connector function or initialize the DME Satellite depend ing on its setting at the startup of the device To switch be tween R...
Page 17: ...UT Connectors These Euroblock connectors receive 8 channel analog audio signals on the DME8i ES These Euroblock connectors receive 4 channel analog audio signals on the DME4io ES OUTPUT Connectors These Euroblock connectors output 8 channel analog audio signals on the DME8o ES These Euroblock connectors output 4 channel analog audio signals on the DME4io ES Precautions for Using a Rack mounted DME...
Page 18: ... Satellite unit by transmitting MIDI com mands from a MIDI sequencer or similar software Connecting to a Computer NOTE Refer to the DME Setup Manual PDF file for details on installing USB MIDI Driver and DME Designer Make sure that the USB MIDI Driver s THRU setting is OFF Refer to Network Settings on page 19 for more information on assigning IP addresses from DME Designer NOTE The computer on whi...
Page 19: ...other devices in the group are assigned as slave The fourth octet of a slave DME Satellite s master ID must be the same value as the fourth octet of the group master DME Satellite s IP address NOTE Subnet mask is fixed at 255 255 255 0 The network address of Gateway is the same as that of IP address The host address of Gateway is automatically set to 254 Assign each of DME series units a unique IP...
Page 20: ...llite units you can use either crossover cables or straight cables In this case from DME Designer set Link Mode on both units to the same setting Devices in different subnet dif ferent network address groups can be connected via a router or layer 3 compliant switching hub NOTE Refer to the DME Setup Manual PDF file for details on installing DME N Network Driver Appropriate IP addresses must first ...
Page 21: ...annot be guaranteed in some cases Use a STP Shielded Twisted Pair cable to prevent electromagnetic interference If you are using multiple DME series units set Link Mode on each unit to the same setting Yamaha recommends that you select 100Base TX for the Link Mode setting You can also connect a supported controller such as the AMX or Crestron and control the DME Satellite remotely For details refe...
Page 22: ...UTILITY UTILITY SCENE SCENE LEVEL LEVEL MUTE MUTE ENTER ENTER CANCEL CANCEL Device Group Group Master DME Satellite IP address 192 168 0 5 Ethernet Cable Ethernet Cable Ethernet Straight Cable Ethernet Straight Cable Ethernet Straight Cable Switching Hub Router or Layer 3 Compliant Switching Hub Computer Port settings Destination network address 192 168 0 0 Subnet mask 255 255 255 0 Gateway 192 16...
Page 23: ...TILITY SCENE SCENE LEVEL LEVEL MUTE MUTE ENTER ENTER CANCEL CANCEL Device Group 1 Device Group 2 Group Master DME Satellite IP address 192 168 0 2 Group Master DME Satellite IP address 192 168 0 3 Ethernet Cable Ethernet Cable Ethernet Straight Cable Ethernet Cable DME64N 24N IP address 192 168 0 100 Master ID 2 DME Satellite IP address 192 168 0 40 Master ID 2 DME Satellite IP address 192 168 0 1...
Page 24: ...ppropriate Owner s Manual Example Connection to EtherSound devices Audio I O Connection About AVS ESMonitor AVS ESMonitor is application software made by the AuviTran SARL for the purpose of monitoring and con trolling an EtherSound system It allows you to make various EtherSound settings such as input output rout ing For details refer to the following website http www auvitran com view php produc...
Page 25: ...repare cables to be attached to a Euroblock plug as shown below Euroblock plug connection 1 Loosen terminal screws 2 Insert cables 3 Securely tighten terminal screws Pull the cables not too strongly to confirm that they are securely connected 4 Insert the Euroblock plug into the Euroblock connector on the rear panel Be sure to use shielded cables Do not tin plate with solder the exposed sections o...
Page 26: ...ers can be connected Be sure to set the dip switch on the rear panel of the DME Satellite to RS 422 page 16 when connecting to AD8HR or AD824 remote head amplifiers Do not change the dip switch setting to any position other than to RS 422 while the devices are connected to prevent possible damage to the device s When connecting to a combination of AD8HR and AD824 head amplifiers be sure to place t...
Page 27: ...rdance with a con nected RS 232C or RS 422 compatible remote controller Do not change the dip switch setting to any other po sition while the devices are connected to prevent possible damage to the device s NOTE Only one mixer can be connected within each device group The digital mixer can be connected to any DME series unit whether it is the group master or a slave unit The ID number of the DME s...
Page 28: ... make connections between DME series units The gain and the phantom power 48V can be controlled from the digital mixer NOTE Only one mixer can be connected within each device group The digital mixer can be connected to any DME series unit whether it is the group master or a slave unit Control signal settings are made using AuviTran s AVS ESMonitor application software The ID number of the DME seri...
Page 29: ... controller such as the AMX or Crestron to DME Satellites via Ethernet and remotely control multiple DME Satellite units NOTE The port used for remote control is specified from DME Designer For details on making this setting refer to the DME Designer Owner s Manual Refer to DME Remote Control Protocol Specifications on the Yamaha web site for more information on communication protocols used to con...
Page 30: ...in Euroblock plug connection on page 25 in this manual NOTE For more information on the CP4SW CP4SF and CP1SF Control Panels refer to the CP4SW CP4SF CP1SF Owner s Manual You can use DME Designer to set up the system so that scene recall operations and User Defined parameter control can be carried out from connected GPI control devices Refer to the DME Designer Owner s Manual for details NOTE You ...
Page 31: ...ta is damaged or corrupted After initialization transfer necessary components from DME Designer 1 While the DME Satellite is turned off set the dip switch on the rear panel to the following position then turn on the power to the unit Four PEAK indicators on the upper row on the front panel light up during the initialization process Four SIGNAL indicators on the lower row of the front panel flash w...
Page 32: ...it via Ethernet Like the DME series units a unique IP address must be assigned to each controller unit Data is transmitted and received via Ethernet cables You can assign and control any function of all DME series units in the same device group via the controller Up to four parameter sets can be assigned to six function keys F1 F6 located above and under the LCD You can control up to 24 parameters...
Page 33: ...el No audio is output Connect the cable properly Did you use AVS ESMonitor to make EtherSound settings such as routing Make sure that the output level set in DME Designer is not too low Make sure that the Mute setting in DME Designer is set to Off You may have designed a scene in DME Designer that mutes audio output You may have tried to use a configuration at 96 kHz that does not support 96 kHz T...
Page 34: ...x Switch turns Bank Select MSB LSB and Program Change transmission on or off Control Change Tx Switch turns Control Change transmission on or off Parameter Change Tx Switch turns Parameter Change transmis sion on or off 3 5 MIDI Rx Switch Program Change Rx Switch turns Bank Select MSB LSB and Program Change reception on or off Control Change Rx Switch turns Control Change reception on or off Param...
Page 35: ...ch is also on however Control Change messages will be received on all MIDI channels regardless of the MIDI Rx Channel setting Control Change parameter resolution is 128 regardless of the effec tive range of the parameter For finer settings use Parameter Change Transmit When the Control Change Tx Switch is on and a parameter is ed ited via DME Designer appropriate Control Change data will be transm...
Page 36: ...arameter Change numbers are assigned to the same parameter the smallest Parameter Change number message will be trans mitted Supplementary Information 2 Setting the Parameter Change Message Parameter Data Values The Parameter change parameter values are expressed as 32 bit in tegers with or without parity A parity bit positive 0 negative 1 is added above the most sig nificant value bit bit 31 Frac...
Page 37: ...nd Off Aux Reset All Cntrls Local ON OFF Mes All Notes OFF sages Active Sense Reset Notes Mode Default Changed Note ON Note OFF Key s Ch s 0 32 1 31 33 95 102 119 1 16 1 16 Ø 1 Ø 2 Ø 0 127 1 1 transmit receive if program change switch is on 2 transmit receive if control change switch is on 3 transmit receive if parameter change switch is on Ø 3 Mode 1 OMNI ON POLY Mode 2 OMNI ON MONO Mode 3 OMNI O...
Page 38: ...amaha dealer Audio is not input or output and is muted due to insufficient DSP resources This error sometimes occurs if you try to operate a configuration at 96 kHz that has been created with a word clock of 48 kHz To operate a configuration at any word clock setting use DME Designer to create a configuration with the word clock set to 96 kHz The network is not communicating properly Connect the E...
Page 39: ... 50ppm Maximum Voltage Gain Gain 60dB RL 600Ω 64dB INPUT to OUTPUT Miscellaneous Power Consumption 40W Dimensions HxDxW 44x361x480 mm Net Weight 4 5kg Temperature range operating 5 to 40 C storage 20 to 60 C Include Accessories AC Power cord CD ROM DME Designer application Mini Euro plug 16P x1 Euro plug 3P x8 Owner s Manual Rubber feetx4 Input Output RL CONDITIONS MIN TYP MAX UNITS INPUT 1 8 OUTP...
Page 40: ...B input level 10dBu GAIN 10dB output level 4 0dBu typ 2 0 0 2 0 dB Input Output RL CONDITIONS MIN TYP MAX UNITS INPUT 1 8 OUTPUT 1 8 600Ω 4dB 20Hz 20kHz fs 48kHz 20Hz 40kHz fs 96kHz GAIN 60dB 0 1 4dB 20Hz 20kHz fs 48kHz 20Hz 40kHz fs 96kHz GAIN 10dB 0 05 22dB 1kHz GAIN 10dB 0 015 fs 48kHz 0 007 fs 96kHz Input Output RL CONDITIONS MIN TYP MAX UNITS INPUT 1 8 OUTPUT 1 8 600Ω 4dB 20Hz 20kHz fs 48kHz ...
Page 41: ...8 600Ω Rs 150Ω GAIN 10dB All input output level controls 0dB 82 79 dBu Input Output RL CONDITIONS MIN TYP MAX UNITS INPUT 1 4 OUTPUT 1 4 600Ω Rs 150Ω GAIN 60dB All input output level controls 0dB 128 EIN 127 EIN dBu 64 dBu Rs 150Ω GAIN 10dB All input output level controls 0dB 82 79 dBu Hum Noise are measured with a 6dB octave filter 12 7kHz equivalent to a 20kHz filter with infinite dB octave atte...
Page 42: ... Terminals GAIN Actual Load Impedance For Use With Nominal Input Level Connector Nominal Max before clip DME8i ES CH INPUT 1 8 DME4io ES CH INPUT 1 4 60dB 3kΩ 50 600Ω Mics 600Ω Lines 60dBu 0 775mV 40dBu 7 75mV EUROBLOCK 5 08mm pitch 10dB 10dBu 2 45V 30dBu 24 5V 1 In these specifications 0dBu is referenced to 0 775 Vrms 2 All AD converters are 24 bit linear 128 times oversampling Fs 48kHz 64 times ...
Page 43: ...ICS NETWORK Connector 100Base TX Ethernet RJ 45 Terminal Format Level Connector GPI IN 0 5V EUROBLOCK 1 3 5mm pitch OUT TTL V 5V Ethernet IEEE802 3 10Base T 100Base TX RJ 45 USB USB 1 1 Function Type B REMOTE RS 232C RS 422 RS 232C RS 422 D SUB 9P Male 1 Inputs 8 channels Outputs 4 channels Inputs Not apply 2 wire Fader mode Outputs Imax pin 16mA Outputs VH 2 5V min VL 0 6V max Pin Connection 1 Tx...
Page 44: ...ner s manual are for information purpose only Yamaha Corp reserves the right to charge or modify products or specifications at any time without prior notice Since specifications equipment or options may not be the same in every locale please check with your Yamaha dealer European models Purchaser User Information specified in EN55103 1 and EN55103 2 Inrush Current 35A Conforms to Environments E1 E...
Page 45: ...e Version 7 G General Specifications 39 GPI Connection 30 GPI Connector 17 Ground Screw 16 group master 9 I ICP1 32 Initialize DME 31 Initializing 31 INPUT OUTPUT Connectors 25 INPUT Connectors 17 Input Output Characteristics 42 M Master and slave setting 19 MASTER Indicator 14 MIDI Data Format 34 MIDI Implementation Chart 37 N NETWORK Connector 16 43 NETWORK Indicator 14 Network Settings 19 O oct...
Page 46: ...troduction to the DME Satellite Controls and Connectors Connecting to a Computer Audio I O Connection Connecting to an External Device Other Functions References DME8i ES DME8o ES DME4io ES Owner s Manual 46 MEMO ...
Page 47: ... ITALY Yamaha Musica Italia S P A Combo Division Viale Italia 88 20020 Lainate Milano Italy Tel 02 935 771 SPAIN PORTUGAL Yamaha Hazen Música S A Ctra de la Coruna km 17 200 28230 Las Rozas Madrid Spain Tel 91 639 8888 SWEDEN Yamaha Scandinavia AB J A Wettergrens Gata 1 Box 30053 S 400 43 Göteborg Sweden Tel 031 89 34 00 DENMARK YS Copenhagen Liaison Office Generatorvej 6A DK 2730 Herlev Denmark T...
Page 48: ...orine free ECF paper with soy ink Yamaha Manual Library http www yamaha co jp manual Yamaha Pro Audio global web site http www yamahaproaudio com 2007 Yamaha Corporation U R G Pro Audio Digital Musical Instrument Division Yamaha Corporation Printed in Japan ...