Yamaha DME24N Owner'S Manual Supplement Download Page 7

 

7

 

Notes for DME64N/DME24N Version 1.2

 

Recovering

The DME64N/24N program update has failed. Restoring 
the previous program. Do NOT turn off the power while 
this display is on the screen. 

Retry the program update. If the update is still 
unsuccessful after several retries, a malfunction is likely. 
Contact a Yamaha electric sound service outlet listed at 
the end of this manual (page 79). 

Saving Failed

Cannot save settings. 

Since this is likely to be a device failure, contact a Yamaha 
electric sound service outlet listed at the end of this 
manual (page 79). 

Saving HA Info

Saving head amp information. Do NOT turn off the power 
while this display is on the screen. 

Saving Setup Info

Saving information (except head amp information) that is 
set in the utility screen. Do NOT turn off the power while 
this display is on the screen. 

Scene Recalling

Recalling a scene. 

Scene Storing

Storing a scene. Do NOT turn off the power while this 
display is on the screen. 

SLOT1 Sync Err

The word clock input from Slot1 is not synchronized with 
the DME64N/24N word clock. 

Recheck the settings for using the word clock that 
synchronizes the DME64N/24N and external devices. 

SLOT2 Sync Err

The word clock input from Slot2 is not synchronized with 
the DME64N word clock. 

Recheck the settings for using the word clock that 
synchronizes the DME64N and external devices. 

SLOT3 Sync Err

The word clock input from Slot3 is not synchronized with 
the DME64N word clock. 

SLOT4 Sync Err

The word clock input from Slot4 is not synchronized with 
the DME64N word clock. 

Slots Overloaded

The electric current being consumed by cards currently 
installed in the slots exceeds the specified value. 

This combination cannot be used. Check the combination 
of cards that are currently installed. 

Store Disable

Scene storing is currently prohibited in the settings. 

This prohibition may have been set by the administrator to 
prevent unexpected data changes caused by erroneous 
user operations. 
Change the setting by going to the Misc page of the utility 
screen and changing the setting for Scene Store to 
“Enable.”

WCLK Unlocked

A valid word clock is not being input or cannot be 
detected. 

Recheck connections and internal settings related to the 
word clock. 

Zone Sync Err

Data from the wrong zone has been input or data has not 
been input. 

Use DME Designer to resend the data.

 

NOTE

 

For information about updated CD-ROM versions to be released in the future, contact the store where you purchased the device, or contact 
Yamaha customer service using the contact information at the end or your “DME64N/24N Owner’s Manual.”

 

Message

Content

Corrective Action

Summary of Contents for DME24N

Page 1: ...ha Pro Audio website http www yamahaproaudio com Added parameters are shown in bold Upgrading Cautions The following parameter will not be reflected in Version 1 2 when it is used to read data created...

Page 2: ...and restarts A THRU connection function has been added Even in an environment with no computer you can check the connections without using DME Designer by directly connecting the DME64N 24N input outp...

Page 3: ...rol Mode Switches to Final Output Stage Parameter Control Mode BANK BANK The channels targeted for operation are shifted by the number of channels built into the DAW controller CH CH The channels targ...

Page 4: ...E64N 24N Owner s Manual has been changed By editing the Monitoring Point List in DME Designer you can select user defined monitoring points in the DME64N 24N Using this function component input output...

Page 5: ...onents other than input output components cannot be arranged The following notes apply when Preparation on page 19 of the DME64N 24N Owner s Manual is started up for the first time The meter does not...

Page 6: ...his manual page 79 Low Battery Battery capacity is running low Stop using the unit immediately and contact a Yamaha electric sound service outlet listed at the end of this manual page 79 MIDI Port In...

Page 7: ...ot synchronized with the DME64N word clock Recheck the settings for using the word clock that synchronizes the DME64N and external devices SLOT3 Sync Err The word clock input from Slot3 is not synchro...

Page 8: ...lip OUTPUT 1 8 150 600 Lines 4dBu 1 23V 24dBu 12 28 Euroblock PHONES 15 8 75mW 150mW Stereo Phone Jack 40 65mW 150mW Input Output RL Conditions Min Typ Max Units CH INPUT 1 8 CH OUTPUT 1 8 600 GAIN 60...