A
1
2
3
4
5
6
7
8
9
10
B
C
D
E
F
G
H
I
J
K
L
M
N
RX-V4600/DSP-AX4600
SCHEMATIC DIAGRAM (OPERATION 2/2)
90
★
All voltages are measured with a 10M
Ω
/V DC electronic volt meter.
★
Components having special characteristics are marked
s
and must be replaced
with parts having specifications equal to those originally installed.
★
Schematic diagram is subject to change without notice.
-0.2
-0.2
15.0
0
0
6.9
6.9
22.7
7.1
7.5
7.5
7.5
3.3
3.3
7.1
7.1
22.7
1.3
6.8
0
0
0
0
5.0
8.8
-20.0
12.1
22.7
10.7
9.8
0
0
7.5
3.4
3.6
-13.4
0.3
-0.3
19.0
AC 30.2
AC 20.2
AC 17.8
AC 7.4
OPERATION (8)
WD403100
O : USED / APPLICABLE
X : NOT USED
P
a
ge 92
to PO
WER (3)_W122
D8
P
age 100
to IBOC_CB3
B8
P
age 99
to DU
AL_HDMI_CB305
J8
P
a
ge 97
to DU
AL_1394_CB6
H8
P
a
ge 89
to OPERA
TION (1)_W901
A3
to PO
WER
TRANSFOMER
to PO
WER
TRANSFOMER
+
–
+
–
1
2
3
V
OUT
5
ON/OFF
4
Oadj
V
IN
V
REF
COM
Voltage
regulator
Over current
protection
circuit
Over heat
protection
circuit
ON/OFF
circuit
Soft
start
Oscillator
ERROR AMP.
PWM COMP.
F/F
Q
S
R
IC460
: PQ1CG2032FZ
Voltage Regulator
IC461
: PQ3RD23
Voltage Regulator
1
Vin
2
Vo
4
Vc
3
GND
Specific IC
IC464
: PQ05RD11
Voltage Regulator
1
Vin
2
Vo
4
Vc
3
GND
Control circuit
IC462
: NJM7809FA
Voltage Regulator
INPUT
OUTPUT
COMMON
Summary of Contents for AX4600
Page 4: ...RX V4600 DSP AX4600 4 RX V4600 DSP AX4600 RX V4600 C model RX V4600 R model RX V4600 T model ...
Page 5: ...RX V4600 DSP AX4600 5 RX V4600 DSP AX4600 RX V4600 K model RX V4600 A model RX V4600 B model ...
Page 84: ...RX V4600 DSP AX4600 84 MEMO MEMO ...
Page 141: ...A B C D E F G H I J 1 2 3 4 5 6 7 RX V4600 DSP AX4600 141 REMOTE CONTROL RAV 354 RAV355 ...
Page 144: ...RX V4600 DSP AX4600 ...