AX-496/396
R553
R552 R560
R561
R553 (L ch)
R561 (R ch)
R552 (L ch)
R560 (R ch)
0.1mV〜10mV
Cut
■
ADJUSTMENTS
Confirmation of Idling Current
•
Right after Power is switched ON, confirm the voltages
measures at R553 (L ch) and R561 (R ch) are between
0.1mV to 10mV.
•
If it exceeds 10mV, open (cut off) R552 (L ch), R560 (R
ch) and reconfirm the voltage.
7