background image

4

1.

T

o assure the finest performance, please read this manual

carefully.  Keep it in a safe place for future reference.

2.

Install this unit in a cool, dry, clean place – away from
windows, heat sources, sources of excessive vibration,
dust, moisture and cold.  Avoid sources of humming
(transformers, motors).  To prevent fire or electrical shock,
do not expose the unit to rain or water.

3.

Never open the cabinet.  If something drops into the set,
contact your dealer.

4.

Do not use force on switches, controls or connection wires.
When moving the unit, first disconnect the power plug and
the wires connected to other equipment. Never pull the
wires themselves.

5.

The openings on the cabinet assure proper ventilation of
the unit.  If these openings are obstructed, the temperature
inside the cabinet will rise rapidly.  Therefore, avoid placing
objects against these openings, and install the unit in well-
ventilated condition. Be sure to allow a space of at least 10
cm behind, 10 cm on the both sides and 20 cm above the
top panel of the unit. Otherwise it may not only damage the
unit, but also cause fire.

6.

Always set the VOLUME control to “– 

” before starting

the audio source play: increase the volume gradually to an
appropriate level after the play has been started.

7.

Do not attempt to clean the unit with chemical solvents;
this might damage the finish.  Use a clean, dry cloth.

8.

Be sure to read the “TROUBLESHOOTING” section
regarding common operating errors before concluding that
the unit is faulty.

9.

When not planning to use this unit for long periods of
time (ie., vacation, etc.), disconnect the AC power plug
from the wall outlet.

10.

To prevent lightning damage, disconnect the AC power
plug and antenna cable when there is an electrical storm.

11.

Grounding or polarization – Precautions should be taken
so that the grounding or polarization of an appliance is not
defeated.

12.

Do not connect audio equipment to the AC outlet on the
rear panel if the equipment requires more power than the
outlet is rated to provide.

13.

Voltage Selector (China and General Models only)
The voltage selector on the rear panel of this unit must
be set for your local main voltage BEFORE plugging
into the AC main supply.
Voltages are 110/120/220/240 V AC, 50/60 Hz.

IMPORTANT
Please record the serial number of this unit in the space
below.

Model:

Serial No.:

The serial number is located on the rear of the unit.
Retain this Owner’s Manual in a safe place for future
reference.

WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.

This unit is not disconnected from the AC power source as
long as it is connected to the wall outlet, even if this unit
itself is turned off. This state is called the standby mode.
In this state, this unit is designed to consume a very small
quantity of power.

For U.K. customers

If the socket outlets in the home are not suitable for the plug
supplied with this appliance, it should be cut off and an
appropriate 3 pin plug fitted. For details, refer to the
instructions described below.
Note: The plug severed from the mains lead must be
destroyed, as a plug with bared flexible cord is hazardous if
engaged in a live socket outlet.

SPECIAL INSTRUCTIONS FOR U.K. MODEL

IMPORTANT:
THE WIRES IN MAINS LEAD ARE COLOURED IN
ACCORDANCE WITH THE FOLLOWING CODE:

Blue: NEUTRAL
Brown: LIVE

As the colours of the wires in the mains lead of this
apparatus may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:
The wire which is coloured BLUE must be connected to the
terminal which is marked with the letter N or coloured
BLACK.  The wire which is coloured BROWN must be
connected to the terminal which is marked with the letter L
or coloured RED.  Making sure that neither core is
connected to the earth terminal of the three pin plug.

CAUTION: READ THIS BEFORE OPERATING YOUR UNIT.

WARNING
Do not change the IMPEDANCE SELECTOR switch
setting while the power to this unit is on, otherwise this
unit may be damaged.

IF THIS UNIT FAILS TO TURN ON WHEN THE
STANDBY/ON SWITCH IS PRESSED;
The IMPEDANCE SELECTOR switch may not be set to
either end closely. If so, set the switch to either end closely.

MAINS

CAUTION

SEE INSTRUCTION MANUAL FOR CORRECT SETTING.

A OR B : 4

MIN. /SPEAKER

A   B : 8

MIN. /SPEAKER

SPEAKERS

A

B

AC OUTLETS

SWITCHED

l00W MAX. TOTAL

A OR B : 8

MIN. /SPEAKER

A   B : 12

MIN. /SPEAKER

IMPEDANCE SELECTOR

SET BEFORE POWER ON

IMPEDANCE SELECTOR

(Europe model)

Summary of Contents for AX-392

Page 1: ...er Natural Sound Integrerad Stereo Förstärkare Amplificatore integrato stereo a Suono Naturale Amplificador integrado estéreo de Sonido Natural Natural Sound Geïntegreerde Stereo Versterker AX 392 OWNER S MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG BRUKSANVISNING MANUALE DI ISTRUZIONI MANUAL DE INSTRUCCIONES GEBRUIKSAANWIJZING B G R T ...

Page 2: ...ces suivantes sont incluses MITGELIEFERTES ZUBEHÖR Nach dem Auspacken überprüfen ob die folgenden Teile vorhanden sind MEDFÖLJANDE TILLBEHÖR Kontrollera efter det apparaten packats upp att följande delar finns med ACCESSORI IN DOTAZIONE Verificare che tutte le parti seguenti siano contenute nell imballaggio dell apparecchio ACCESORIOS INCLUIDOS Desembale el aparato y verificar que los siguientes a...

Page 3: ...ance Drive Capability Continuously Variable LOUDNESS Control CD DIRECT AMP Switch to Reproduce the Purest CD Sound Remote Control Capability SUPPLIED ACCESSORIES 2 FEATURES 3 CAUTION 4 NOTES ABOUT THE REMOTE CONTROL TRANSMITTER 5 CONNECTIONS 6 CONTROLS AND THEIR FUNCTIONS 8 OPERATIONS 11 TROUBLESHOOTING 14 SPECIFICATIONS 15 FEATURES CONTENTS ...

Page 4: ...et for your local main voltage BEFORE plugging into the AC main supply Voltages are 110 120 220 240 V AC 50 60 Hz IMPORTANT Please record the serial number of this unit in the space below Model Serial No The serial number is located on the rear of the unit Retain this Owner s Manual in a safe place for future reference WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS UNIT TO...

Page 5: ...of time If batteries leak dispose of them immediately Avoid touching the leaked material or letting it come in contact with clothing etc Clean the battery compartment thoroughly before installing new batteries Remote control transmitter operation range Notes There should be no large obstacles between the remote control transmitter and the main unit If the remote control sensor is directly illumina...

Page 6: ...output or input terminals of each component to the same numbered terminals of this unit 1 2 Refer to ABOUT THE ACCESSORY TERMINALS on page 7 MD PHONO CD TUNER AUX TAPE PLAY REC PLAY REC 2 1 3 4 3 4 GND MAINS CAUTION SEE INSTRUCTION MANUAL FOR CORRECT SETTING A OR B 4ΩMIN SPEAKER A B 8ΩMIN SPEAKER SPEAKERS A B AC OUTLETS SWITCHED l00W MAX TOTAL A OR B 8ΩMIN SPEAKER A B 12ΩMIN SPEAKER IMPEDANCE SELE...

Page 7: ...tlets is controlled by this unit s STANDBY ON switch or the provided remote control transmitter s POWER key These outlets will supply power to any component whenever this unit is turned on The maximum power total power consumption of components that can be connected to the SWITCHED AC OUTLET S is 100 watts GND terminal For turntable use Connecting the ground wire of the turntable to this terminal ...

Page 8: ... tape deck connected to the TAPE terminals on the rear of this unit is used for recording you can monitor the sounds being recorded by pressing TAPE MONITOR so that TAPE MONITOR indicator lights up 8 INPUT selector When turned selects a program source to listen to The input source indicator for the currently selected source lights up 9 CD DIRECT AMP switch Press this switch inward to listen to a C...

Page 9: ... response The 0 position produces flat response D BALANCE control Adjusts the balance of the output volume to the left and right speakers to compensate for sound imbalance caused by speaker location or listening room conditions E Continuously variable LOUDNESS control Used to compensate for the human ears loss of sensitivity to high and low frequency ranges at low volume F Control door See below f...

Page 10: ...k For a single cassette deck with automatic reverse function pressing DIR A will reverse the direction of tape running 2 Tuner keys Control tuner Selects higher preset station number Selects lower preset station number A B C D E Selects the group A E of preset station numbers 3 CD player keys Control compact disc player DISC is applicable only to compact disc changer REMOTE CONTROL TRANSMITTER The...

Page 11: ... 5 5 4 3 3 2 2 l l 0 4 NATURAL SOUND STEREO AMPLIFIER AX 392 SPEAKERS PHONES A ON B OFF VOLUME INPUT MONITOR CD DIRECT AMP l6 20 28 40 60 l2 8 4 2 0 dB STANDBY ON l 5 7 4 3 2 l FLAT l0 9 8 30dB 4 7 3 2 3 7 1 6 Lights up l6 20 28 40 60 l2 8 4 2 0 dB VOLUME STANDBY ON INPUT CD MD TAPE TUNER AUX PHONO l6 20 28 40 60 l2 8 4 2 0 dB VOLUME SPEAKERS A ON OFF B When you finish using this unit Press the ST...

Page 12: ...y the source and then turn the VOLUME control up to confirm the input source 3 Begin recording on the tape deck or MD recorder etc connected to this unit 4 If the tape deck connected to the TAPE terminals on the rear of this unit is used for recording you can monitor the sounds being recorded by pressing the TAPE MONITOR switch so that the TAPE MONITOR indicator lights up Note VOLUME BASS TREBLE B...

Page 13: ...ible CD sound from your CD player by pressing this switch inward By doing so CD s input signals are sent to the built in special amplifier for CD directly bypassing the INPUT selector the BASS TREBLE BALANCE and LOUDNESS controls and then sent to the power amplifier This signal routing reproduces the purest CD sound eliminating any alterations to the CD signals This control provides compensation f...

Page 14: ...correct setting of the BALANCE control Incorrect cord connections The and wires are connected in reverse at the amplifier or speakers Incorrect cord connections No connection from the turntable to the GND terminal The record is being played on a turntable with an MC cartridge The component connected to the REC terminals of this unit is turned off This unit is in the standby mode The LOUDNESS contr...

Page 15: ...0 0 5 dB Total Harmonic Distortion 20 Hz to 20 kHz PHONO MM to REC OUT 1V 0 02 CD TUNER AUX MD TAPE to SP OUT 30W 8 ohms 0 02 Signal to Noise Ratio IHF A Network PHONO MM 5 mV Input Shorted 82 dB CD TUNER AUX MD TAPE Shorted CD DIRECT AMP ON 108 dB Residual Noise IHF A Network CD DIRECT AMP ON 35 µV CD DIRECT AMP OFF 100 µV Channel Separation CD TUNER AUX MD TAPE Input 5 1 k ohms Terminated 1 kHz ...

Page 16: ... RELLINGEN BEI HAMBURG F R OF GERMANY YAMAHA ELECTRONIQUE FRANCE S A RUE AMBROISE CROIZAT BP70 CROISSY BEAUBOURG 77312 MARNE LA VALLEE CEDEX02 FRANCE YAMAHA ELECTRONICS UK LTD YAMAHA HOUSE 200 RICKMANSWORTH ROAD WATFORD HERTS WD1 7JS ENGLAND YAMAHA SCANDINAVIA A B J A WETTERGRENS GATA 1 BOX 30053 400 43 VÄSTRA FRÖLUNDA SWEDEN YAMAHA MUSIC AUSTRALIA PTY LTD 17 33 MARKET ST SOUTH MELBOURNE 3205 VIC ...

Reviews: