Error messages from YPAO
If any error message is displayed during the measurement, resolve the problem and
perform YPAO again.
Error message
TV screen
ENHANCER
LINK
ECO
MASTER
OUT
2
-R
es
Hi
YPAO VOL. A - DRC
SLEEP
STEREO
PARTY
TUNED
ZONE
3 B
2 A
FPR
SBL
SB
SBR
FPL
MUTE VIRTUAL
E-5:NOISY
VOL.
SL
SW
SR
E-9:CANCEL
Front display
Error message
Cause
Remedy
E-1:No Front SP
(E-1:NO FRNT SP)
Front speakers are not
detected.
Exit YPAO, turn off the unit, and then
check the speaker connections.
E-2:No Sur. SP
(E-2:NO SUR SP)
One of the surround
speakers cannot be
detected.
E-3:No F.PRNS SP
(E-3:NO FPR SP)
One of the presence
speakers cannot be
detected.
E-4:No Sur. Back SP
(E-4:NO SUR BACK SP)
One of the surround back
speaker cannot be
detected.
E-5:Noisy
(E-5:NOISY)
The noise is too loud.
Keep the room quiet and retry YPAO. If
you select “PROCEED”, YPAO takes the
measurement again and ignores any
noise detected.
E-6:Check Sur.
(E-6:CHECK SUR)
Surround back speakers are
connected, but no surround
speakers are connected.
Surround speakers need to be
connected in order to use surround back
speakers. Exit YPAO, turn off the unit,
and then reconnect the speakers.
E-7:No MIC
(E-7:NO MIC)
The YPAO microphone has
been removed.
Connect the YPAO microphone to the
YPAO MIC jack firmly and retry YPAO.
E-8:No Signal
(E-8:NO SIGNAL)
The YPAO microphone
cannot detect test tones.
Connect the YPAO microphone to the
YPAO MIC jack firmly and retry YPAO. If
this error occurs repeatedly, contact the
nearest authorized Yamaha dealer or
service center.
E-9:User Cancel
(E-9:CANCEL)
The measurement has been
canceled.
Retry or exit YPAO as necessary.
E-10:Internal Err.
(E-10:INTERNAL)
An internal error has
occurred.
Exit YPAO, and turn off and on the unit. If
this error occurs repeatedly, contact the
nearest authorized Yamaha dealer or
service center.
NOTE
▪ Text in parentheses denotes indicators on the front display.
▪ To exit the YPAO measurement for resolving the problem, use the cursor keys to select “EXIT” and press
ENTER.
▪ For the error messages E-5 and E-9 only, you can proceed with the current YPAO measurement. Press
ENTER, and then use the cursor keys to select “PROCEED” and press ENTER.
▪ To retry the YPAO measurement from beginning, press ENTER, and then use the cursor keys to select
“RETRY” and press ENTER.
En
37