A-S1000
19
(Side A)
MAIN (1) P.C.B.
CB55
VR101
R ch
CB75
DC +4.0 to +8.0 mV
VR201
Front side
(Side A)
MAIN (2) P.C.B.
L ch
10
0
minute
+4.0 to +8.0 mV
DC voltage /
DC電圧
1
10
20
mV
VR201
CB75
DC +4.0 to +8.0 mV
MAIN (2) P.C.B.
L ch
CB55
DC +4.0 to +8.0 mV
MAIN (1) P.C.B.
R ch
VR101
Fig. 1
■
AMP ADJUSTMENT /
アンプ部調整
● アイドリング調整
●
Idling Adjustment
条件
・ 電源を入れてから20分経過後に調整を始めます。
・ 無入力信号
・ 無負荷
アイドリング調整
CB75(Lch)/CB55(Rch)のDC電圧が+4.0〜+8.0 mV
になるように、VR201(Lch)/VR101(Rch)を調整し
ます。 (Fig. 1)
Condition
•
Start adjustment 20 minutes or more after the
power is turned on.
•
Non loaded condition
Idling Adjustment
Adjust VR201 (Lch)/VR101 (Rch) so that the DC volt-
age of CB75 (Lch)/CB55 (Rch) b4.0 to
+8.0mV. (Fig. 1)
Precaution for handling measuring instrument
The ground side of the measuring instrument to be con-
nected to the speaker terminal of this unit must be kept in
floating condition because this unit is equipped with the
floating balanced power amplifier.
計測器取り扱い上の注意
本機はフローティングバランスパワーアンプを搭載して
いるので、本機のスピーカー出力端子に接続する計測器
のアース側はフローティング状態にする必要がありま
す。